-- ********************************************************************
-- CISCO-MEGACO-EXT-MIB

-- This MIB is extended from CISCO-IETF-MEGACO-MIB

-- May 2004, Margaret Hsieh

-- Copyright (c) 2003, 2004, 2005, 2006 by Cisco Systems, Inc.
-- All rights reserved.
-- ********************************************************************

CISCO-MEGACO-EXT-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE,
    Unsigned32,
    TimeTicks,
    Integer32,
    Gauge32,
    Counter32
        FROM SNMPv2-SMI
    TEXTUAL-CONVENTION,
    TruthValue,
    RowStatus,
    TimeStamp
        FROM SNMPv2-TC
    MODULE-COMPLIANCE,
    OBJECT-GROUP
        FROM SNMPv2-CONF
    InetAddress,
    InetAddressType
        FROM INET-ADDRESS-MIB
    SnmpAdminString
        FROM SNMP-FRAMEWORK-MIB
    CiscoPort
        FROM CISCO-TC
    ciscoExperiment
        FROM CISCO-SMI
    CMgcGroupIndex
        FROM CISCO-MGC-MIB
    CvcSpeechCoderRate
        FROM CISCO-VOICE-COMMON-DIAL-CONTROL-MIB
    CCallControlProfileIndex,
    CCallControlProfileIndexOrZero
        FROM CISCO-MEDIA-GATEWAY-MIB
    Counter32SinceReset
        FROM CISCO-ATM-TRUNK-MIB
    cmedGatewayId,
    cmedGatewayLinkId,
    cmedTerminationsEntry,
    cmedGatewayConfigEntry,
    cmedGatewayStatsEntry
        FROM CISCO-IETF-MEGACO-MIB;


ciscoMegacoExtMIB MODULE-IDENTITY
    LAST-UPDATED    "200608291200Z"
    ORGANIZATION    "Cisco Systems, Inc."
    CONTACT-INFO
            "Cisco Systems
            Customer Service
            Postal: 170 W Tasman Drive
            San Jose, CA 95134
            USA
            Tel: +1 800 553-NETS
            E-mail: cs-voice-gateway@cisco.com"
    DESCRIPTION
            "The MIB module is an extension of CISCO-IETF-MEGACO-MIB.
            It defines the attributes of ITU H.248 protocol."
    REVISION        "200608291200Z"
    DESCRIPTION
            "
            Added new objects to cmedxGatewayConfigTable
                cmedxGatewayDomainName,
                cmedxGatewayCmbDnAndPortInMID."
    REVISION        "200604211200Z"
    DESCRIPTION
            "Deprecated the following object:
            cmedxGatewayProvisionRespTime

            Added new objects to cmedxGatewayConfigTable
            cmedxGatewayMgProvisionRspTime,
            cmedxGatewayMgcProvisionRspTime,
            cmedxGatewayMgOrigPendLimit,
            cmedxGatewayMgcOrigPendLimit
            for ETSI TISPAN compliance.     

            Added new objects to cmedxCommandStatsTable
            cmedxCmdNumAddPendings,
            cmedxCmdNumSubtractPendings,
            cmedxCmdNumMovePendings,
            cmedxCmdNumModifyPendings,
            cmedxCmdNumAuditValPendings,
            cmedxCmdNumAuditCapPendings,
            cmedxCmdNumNotifyPendings,
            cmedxCmdNumSrvChgFromMgcPendings,
            cmedxCmdNumSrvChgFromMgPendings,
            cmedxCmdTotalPendings.
            "
    REVISION        "200511031200Z"
    DESCRIPTION
            "Added new values from pkgGRI to pkgXnq to
            CH248Packages.

            Added new objects to cmedxCallReduceControlTable
                cmedxCrrNotifyState,
                cmedxCrrNotifyEnabled.
                cmedxCurrentCallState

            Added new objects to cmedxProfileTable
                cmedxProfileComfortNoiseGenerate

            Added new objects to cmedxCommandStatsTable
                cmedxCmdTotalFails,
                cmedxCmdTotalSucceeds,
                cmedxCmdTotal.

            Added the following tables -
                cmedxOverloadControlTable,
                cmedxCommandProcStatsTable,
                cmedxOverloadStatsTable,
                cmedxOverloadResourceStatsTable

            Added the following objects to cmedxGatewayConfigTable:   
                cmedxGatewaySctpAssocId,
                cmedxGatewaySrvChgProfile,
                cmedxGatewaySrvChgProfileVer,
                cmedxGatewayMsgTokenType."
    REVISION        "200504251200Z"
    DESCRIPTION
            "Added 6 more packet ids in CH248Packages:
            pkgBCAS      (20),
            pkgRBS       (21),
            pkgOSES      (22),
            pkgAMET      (23),
            pkgBCASAddr  (24),
            pkgCASBlock  (25)
            to handle the CAS state of the gateway link."
    REVISION        "200406031200Z"
    DESCRIPTION
            "(a) Note: There is a typo in the MIB.
            The UNITS of the object cmedxGatewayInactivityTime
            has been changed to '10 milliseconds'. 
            (b) Added two new objects, 
               cmedxGatewayAdminAction 
               cmedxGatewayServiceState
            to handle the service state of the gateway link.
            (c) Added four new objects, 
               cmedxProfileOriginatingCotTx
               cmedxProfileOriginatingCotRx
               cmedxProfileTerminatingCotTx
               cmedxProfileTerminatingCotRx
            to handle COT.
            (d) Added pktLLTR(19) to CH248Packages TC.
            (e) Added 3 new objects, 
               cmedxGatewayDynamicTpktVersion
               cmedxGatewayMaxCommandMsgSize
               cmedxGatewayMaxReplyMsgSize
            for TCP layer and the maximum size of command and reply
            message of H248.
            "
    REVISION        "200310131200Z"
    DESCRIPTION
            "Initial version of this MIB module."
          ::= { ciscoExperiment 104 }


-- ********************************************************************

-- OID For the MIB

-- ********************************************************************
ciscoMegacoExtMIBNotifications  OBJECT IDENTIFIER
    ::= { ciscoMegacoExtMIB 0 }

ciscoMegacoExtMIBObjects  OBJECT IDENTIFIER
    ::= { ciscoMegacoExtMIB 1 }

cmedxConfig  OBJECT IDENTIFIER
    ::= { ciscoMegacoExtMIBObjects 1 }

cmedxStats  OBJECT IDENTIFIER
    ::= { ciscoMegacoExtMIBObjects 2 }

-- *****************************************************************
-- Abbreviations/Terminologies

-- ATM - Asynchronous Transfer Mode

-- DTMF - Dual Tone Multi-Frequency

-- Media Gateway ID - An unique identifier specifies a logical media
-- gateway. It is defined by object cmedGatewayId
-- in CISCO-IETF-MEGACO-MIB and has the same
-- meaning with cmgwIndex in
-- CISCO-MEDIA-GATEWAY-MIB.

-- Media Gateway Link - A signaling channels that is identified by an
-- IP address and a UDP port of a media gateway.
-- A media gateway can have one or more links
-- (one or more signaling channels). It is
-- represented by cmedGatewayLinkId in
-- CISCO-IETF-MEGACO-MIB.

-- H.248 Association - A media gateway communicates with a group of
-- MGCs by a media gateway link. This media
-- gateway and the MGC group form an H.248
-- association.

-- MG   - Media Gateway

-- MGC  - Media Gateway Controller

-- PSTN - Public Switched Telephone Network

-- PDN - Packet Data Network

-- RTP - Real-time Transport Protocol

-- SCN - Switched Circuit Network

-- DS  - Digital Subscriber

-- MID - Media Gateway ID

-- DNS - Domain Name Server

-- *****************************************************************

-- ********************************************************************

-- Textual conventions

-- ********************************************************************

CH248Packages ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
            "This textual convention defines all possible packages in
            H.248 protocol."
    SYNTAX          BITS {
                        pkgG(0),
                        pkgRoot(1),
                        pkgToneGen(2),
                        pkgToneDet(3),
                        pkgDG(4),
                        pkgDD(5),
                        pkgCG(6),
                        pkgCD(7),
                        pkgCT(8),
                        pkgNT(9),
                        pkgRTP(10),
                        pkgTDMC(11),
                        pkgAN(12),
                        pkgBCG(13),
                        pkgXCG(14),
                        pkgSrvTn(15),
                        pkgXsrvTn(16),
                        pkgChp(17),
                        pkgIT(18),
                        pkgLLTR(19),
                        pkgBCAS(20),
                        pkgRBS(21),
                        pkgOSES(22),
                        pkgAMET(23),
                        pkgBCASAddr(24),
                        pkgCASBlock(25),
                        pkgGRI(26),
                        rtcpxr(27),
                        xrbm(28),
                        qac(29),
                        pkgDS(30),
                        pkgETerm(31),
                        pkgXnq(32),
                        pkgCTYP(33),
                        pkgIPFAX(34)
                    }

CMedxCotTones ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
            "This textual convention defines the tones to be used
            between originating gateway and terminating gateway in 
            the COT (Continuity Test).
            co1 (1) - CO1 is either 2000Hz or 2010Hz depending on
                      the region/country regulation.
            co2 (2) - CO2 is always 1780Hz."
    SYNTAX          INTEGER  {
                        co1(1),
                        co2(2)
                    }
-- *********************************************************************

-- cmedxGatewayConfigTable

-- This table is extended from cmedGatewayConfigTable of
-- CISCO-IETF-MEGACO-MIB.

-- *********************************************************************

cmedxGatewayConfigTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxGatewayConfigEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "The Cisco media gateway configuration extended table defines
            the parameters related to the configuration of the media
            gateway in H.248 protocol.

            Each entry represents an instance of an H.248 Gateway Link."
    ::= { cmedxConfig 1 }

cmedxGatewayConfigEntry OBJECT-TYPE
    SYNTAX          CmedxGatewayConfigEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "An entry containing additional H.248 protocol related
            configuration applicable to a media gateway.
            The following objects must be provided when the entry
            is created, and they can not be modified after the entry 
            becomes active:
                cmedxGatewayMgcGroupIndex,
                cmedxGatewayIpAddressIndex."
    AUGMENTS           { cmedGatewayConfigEntry  } 
 
    ::= { cmedxGatewayConfigTable 1 }

CmedxGatewayConfigEntry ::= SEQUENCE {
        cmedxGatewayMgcGroupIndex       CMgcGroupIndex,
        cmedxGatewayIpAddressIndex      Unsigned32,
        cmedxGatewayAssociationId       Unsigned32,
        cmedxGatewayMaxContexts         Unsigned32,
        cmedxGatewayMaxTermsInContext   Unsigned32,
        cmedxGatewayMgExecTime          Unsigned32,
        cmedxGatewayMgcExecTime         Unsigned32,
        cmedxGatewayProvisionRespTime   Unsigned32,
        cmedxGatewayNumConnRetries      Unsigned32,
        cmedxGatewayMaxWaitingDelay     Unsigned32,
        cmedxGatewayRestartDelay        Unsigned32,
        cmedxGatewayRespRetentionTime   Unsigned32,
        cmedxGatewayInitialRtt          Unsigned32,
        cmedxGatewayInactivityTime      Unsigned32,
        cmedxGatewayHeaderAddrType      InetAddressType,
        cmedxGatewayDownServiceDelay    Integer32,
        cmedxGatewayActiveMgcAddress    InetAddress,
        cmedxGatewayActiveMgcDomain     SnmpAdminString,
        cmedxGatewayActiveMgcPortNum    CiscoPort,
        cmedxGatewayStateChangeReason   INTEGER ,
        cmedxGatewayStateChangeMethod   INTEGER ,
        cmedxGatewayAdminAction         INTEGER ,
        cmedxGatewayServiceState        INTEGER ,
        cmedxGatewayDynamicTpktVersion  TruthValue,
        cmedxGatewayMaxCommandMsgSize   Unsigned32,
        cmedxGatewayMaxReplyMsgSize     Unsigned32,
        cmedxGatewaySctpAssocId         Unsigned32,
        cmedxGatewaySrvChgProfile       SnmpAdminString,
        cmedxGatewaySrvChgProfileVer    Unsigned32,
        cmedxGatewayMsgTokenType        INTEGER ,
        cmedxGatewayMgProvisionRspTime  Unsigned32,
        cmedxGatewayMgcProvisionRspTime Unsigned32,
        cmedxGatewayMgOrigPendLimit     Unsigned32,
        cmedxGatewayMgcOrigPendLimit    Unsigned32,
        cmedxGatewayDomainName          SnmpAdminString,
        cmedxGatewayCmbDnAndPortInMID   TruthValue
}

cmedxGatewayMgcGroupIndex OBJECT-TYPE
    SYNTAX          CMgcGroupIndex
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the MGC group parameters associated
            with MGC group index. Those parameters are for the 
            communication between this media gateway and the MGCs 
            in the group. 
            The value of this object is the same as cMgcGrpIndex
            of cMgcGrpParamTable." 
    ::= { cmedxGatewayConfigEntry 1 }

cmedxGatewayIpAddressIndex OBJECT-TYPE
    SYNTAX          Unsigned32 (1..64 )
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the media gateway IP address.
            It is the index of the entry in cMediaGwIpConfigTable
            which defines the media gateway address over control
            type PVC." 
    ::= { cmedxGatewayConfigEntry 2 }

cmedxGatewayAssociationId OBJECT-TYPE
    SYNTAX          Unsigned32 (1..65535 )
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object indicates the unique identification of the
            H.248 association assigned by the H.248 Stack." 
    ::= { cmedxGatewayConfigEntry 3 }

cmedxGatewayMaxContexts OBJECT-TYPE
    SYNTAX          Unsigned32 (1..4294967295 )
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "Maximum number of contexts is allowed in this media
            gateway link."
    DEFVAL          { 100 } 
    ::= { cmedxGatewayConfigEntry 4 }

cmedxGatewayMaxTermsInContext OBJECT-TYPE
    SYNTAX          Unsigned32 (1..100 )
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "Maximum number of terminations per context in this media
            gateway link."
    DEFVAL          { 10 } 
    ::= { cmedxGatewayConfigEntry 5 }

cmedxGatewayMgExecTime OBJECT-TYPE
    SYNTAX          Unsigned32 (0..65535 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the interval within which the MGC
            expects a response to any transaction from the MG (exclusive
            of network delay specified by the object 
            cmedxGatewayInitialRtt)."
    REFERENCE       "RFC2885, E.2.1 Properties."
    DEFVAL          { 5000 } 
    ::= { cmedxGatewayConfigEntry 6 }

cmedxGatewayMgcExecTime OBJECT-TYPE
    SYNTAX          Unsigned32 (0..65535 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the interval within which the MG
            should expects a response to any transaction from the MGC
            (exclusive of network delay specified by the object
            cmedxGatewayInitalRtt)."
    REFERENCE       "RFC2885, E.2.1 Properties."
    DEFVAL          { 5000 } 
    ::= { cmedxGatewayConfigEntry 7 }

cmedxGatewayProvisionRespTime OBJECT-TYPE
    SYNTAX          Unsigned32 (0..65535 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          deprecated
    DESCRIPTION
            "This object specifies the time within which to expect a
            Pending Response if a transaction cannot be completed in
            the media gateway and in the MGCs of the media gateway 
            link.

            The value of this object should be less than
            the value of cmedxGatewayMgExecTime and the value
            of cmedxGatewayMgcExecTime.

            This object is depricated due to the object name,
            default value and description are wrong.  This object 
            is replaced by 'cmedxGatewayMgProvisionRspTime'."
    DEFVAL          { 2000 } 
    ::= { cmedxGatewayConfigEntry 8 }

cmedxGatewayNumConnRetries OBJECT-TYPE
    SYNTAX          Unsigned32 (0..100 )
    UNITS           "times"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "The number of times the media gateway retries to
            connect to MGC before it sends out disconnect command."
    DEFVAL          { 11 } 
    ::= { cmedxGatewayConfigEntry 9 }

cmedxGatewayMaxWaitingDelay OBJECT-TYPE
    SYNTAX          Unsigned32 (0..600000 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "When a media gateway is powered on, it should initiate
            a restart timer to a random value, uniformly distributed 
            between 0 and the value specified in this object (the
            maximum waiting delay, MWD). After restart timer timeout,
            the media gateway can initiate the ServiceChange 
            transaction. This is a way to prevent the MGC is swamped
            by many gateways powered up at the same time."
    DEFVAL          { 3000 } 
    ::= { cmedxGatewayConfigEntry 10 }

cmedxGatewayRestartDelay OBJECT-TYPE
    SYNTAX          Unsigned32 (0..600 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies The time delay before the media
            gateway accept any call from MGC after it sends 
            the command 'ServiceChange' with a 'Restart'."
    DEFVAL          { 200 } 
    ::= { cmedxGatewayConfigEntry 11 }

cmedxGatewayRespRetentionTime OBJECT-TYPE
    SYNTAX          Unsigned32 (0..65535 )
    UNITS           "seconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the time till which the responses
            should be retained before they are sent if they receive 
            a repetition of a transaction that is still being 
            executed."
    DEFVAL          { 30 } 
    ::= { cmedxGatewayConfigEntry 12 }

cmedxGatewayInitialRtt OBJECT-TYPE
    SYNTAX          Unsigned32 (0..65535 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "Initial round-trip time for the H.248 transaction to
            be responded. It reflects the network delay time."
    DEFVAL          { 1000 } 
    ::= { cmedxGatewayConfigEntry 13 }

cmedxGatewayInactivityTime OBJECT-TYPE
    SYNTAX          Unsigned32 (0..65535 )
    UNITS           "10 milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the the period of silence
            between messages from MGC. If the period of silence
            exceeds the value of this object, then a Notify command 
            with inactive MGC event is generated from the media gateway.

            The value of 0 is to disable the inactivity detection
            on the media gateway."
    REFERENCE
            "H.248 Gateway Control Protocol,  Version 2
                     Inactivity Timer Package (IT)."
    DEFVAL          { 1000 } 
    ::= { cmedxGatewayConfigEntry 14 }

cmedxGatewayHeaderAddrType OBJECT-TYPE
    SYNTAX          InetAddressType
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION     "The address type in the H.248 message header."
    DEFVAL          { ipv4 } 
    ::= { cmedxGatewayConfigEntry 15 }

cmedxGatewayDownServiceDelay OBJECT-TYPE
    SYNTAX          Integer32 (-1..65535 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the grace period before the media
            gateway link to be taken out of service.

            The value of 0 means to take the media gateway link out
            of service forcefully without any delay.
            The value of -1 means not to take the media gateway link
            out of service until all currently active contexts have
            been cleared."
    DEFVAL          { 0 } 
    ::= { cmedxGatewayConfigEntry 16 }

cmedxGatewayActiveMgcAddress OBJECT-TYPE
    SYNTAX          InetAddress
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The address of the currently active MGC in this media
            gateway link." 
    ::= { cmedxGatewayConfigEntry 17 }

cmedxGatewayActiveMgcDomain OBJECT-TYPE
    SYNTAX          SnmpAdminString (SIZE  (0..64))
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The domain name of the currently active MGC in this media
            gateway link." 
    ::= { cmedxGatewayConfigEntry 18 }

cmedxGatewayActiveMgcPortNum OBJECT-TYPE
    SYNTAX          CiscoPort
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The transport layer port number of the currently active
            MGC in this media gateway link." 
    ::= { cmedxGatewayConfigEntry 19 }

cmedxGatewayStateChangeReason OBJECT-TYPE
    SYNTAX          INTEGER  {
                        mgcDirected(1),
                        mgDirected(2),
                        mgcNotReachable(3),
                        numRetriesExpired(4)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object indicates the reason for the operational state
            change (cmedGatewayOperStatus) in the media gateway link.

            mgcDirected (1) - The state change is directed from MGC.
            mgDirected  (2) - The state change is directed from MG.
            mgcNotReachable (3) - The transport address of MGC is not
                                  reachable.
            numRetriesExpired (4) - The number of retires for connecting
                          MGC has exhausted (cmedxGatewayNumConnRetries)." 
    ::= { cmedxGatewayConfigEntry 20 }

cmedxGatewayStateChangeMethod OBJECT-TYPE
    SYNTAX          INTEGER  {
                        other(1),
                        graceful(2),
                        forced(3),
                        handoff(4),
                        failover(5),
                        restart(6),
                        disconnect(7),
                        cancelGraceful(8)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object indicates the method for the operational state
            change (cmedGatewayOperStatus) in the media gateway link.

            other    (1) - None of the methods listed below.
            graceful (2) - The state change to 'down(2)' is by the way 
                           of graceful out of service.
            forced   (3) - The state change to 'down(2)' is by the way
                           of forced out of service. 
            handoff  (4) - The state change is by the way that the MGC
                           hands off to another MGC.
            failover (5) - The state change is by the way that MG 
                           reconnects to current MGC because of the 
                           failure of previous MGC. 
            restart  (6) - The state change is by the way that MG or MGC
                           restarts.
            disconnect (7) - The state change is by the way that MG 
                           brings down the service because of the MG port
                           has been modified, the number of retries
                           has exhausted, or the inactivity timer has
                           expired.
            cancelGraceful (8) - After issuing graceful out of service 
                           with a delay (cmedxGatewayDownServiceDelay>0),
                           MG then sends an in-service command before the
                           delay has been expired." 
    ::= { cmedxGatewayConfigEntry 21 }

cmedxGatewayAdminAction OBJECT-TYPE
    SYNTAX          INTEGER  {
                        up(1),
                        downForceful(2),
                        downGraceful(3),
                        cancelGraceful(4)
                    }
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the action that users used to
            change the service state of the media gateway link.
            This object can be modified while the entry is active.

            up            (1) - Bring the service state up. The value
                                of cmedxGatewayDownServiceDelay will be
                                ignored.
            downForceful  (2) - Bring the service state down without any
                                delay. All current active calls will be
                                torn down forcefully. The value of 
                                cmedxGatewayDownServiceDelay must be 0.
            downGraceful  (3) - Bring the service state down but wait 
                                until currently active calls are 
                                terminated by users. The value of
                                cmedxGatewayDownServiceDelay must be
                                greater than 0.
            cancelGraceful(4) - While waiting for all currently active
                                calls to be terminated by users during
                                the downGraceful action, this 
                                value can be used to cancel the previous
                                action 'downGraceful(3)'.
                                The value of cmedxGatewayDownServiceDelay
                                will be ignored.
            "
    DEFVAL          { downForceful } 
    ::= { cmedxGatewayConfigEntry 22 }

cmedxGatewayServiceState OBJECT-TYPE
    SYNTAX          INTEGER  {
                        inService(1),
                        pendingIs(2),
                        outOfService(3),
                        pendingFoos(4),
                        pendingGoos(5),
                        mgcDirectOos(6)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object indicates current operation status of the media
            gateway link.

            inService    (1) - The media gateway link is in-service.
            pendingIs    (2) - The media gateway link is in the process
                               of establishing the service between MG 
                               and MGC. 
            outOfService (3) - The service of the media gateway link is
                               completely down due to the action of
                               setting cmedxGAtewayAdminAction to 
                               'downForceful(2)' or to 'downGraceful(3)'. 
            pendingFoos  (4) - The media gateway link is in the process
                               of bringing down the service in response to
                               the action of setting object 
                               cmedxGAtewayAdminAction to 
                               'downForceful(2)'.
            pendingGoos  (5) - The media gateway link is in the process
                               of bringing down the service in response to
                               the action of setting object
                               cmedxGAtewayAdminAction to 
                               'downGraceful(3)'.
            mgcDirectOos (6) - The media gateway link is out-of-service
                               due to MGC disable the link. 
                               This state should occur very rarely,
                               the way to recover from this state is to set
                               cmedxGAtewayAdminAction to 'up(1)' or
                               'downForceful(2)'
            " 
    ::= { cmedxGatewayConfigEntry 23 }

cmedxGatewayDynamicTpktVersion OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the TPKT header version that is
            dynamically assigned based on the size of the packet 
            presented to TCP layer.
            The TPKT header version is set to 3 when the size of packet
            is represented by 2 octets of packet length field for 
            the message (TPDU) sizes less than or equal to 65531 octets.

            If this object is set to 'true':
            - The TPKT header version is set to 4 when the size of packet 
              is represented by 4 octets of packet length field for
              the message (TPDU) sizes greater than 65531 octets.

            If this object is set to 'false':
            - An error in message is sent to MGC if the TPDU
              size exceeds 65531 octets indicating that response size 
              exceeded maximum PDU size.
            "
    REFERENCE       "RFC1006"
    DEFVAL          { true } 
    ::= { cmedxGatewayConfigEntry 24 }

cmedxGatewayMaxCommandMsgSize OBJECT-TYPE
    SYNTAX          Unsigned32 (1..4096 )
    UNITS           "Kbyte"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the maximum message size on
            this gateway link for a H248 transaction containing
            the media gateway initiated commands. 
            For example, this object would limit the size of a
            H248 transaction containing the media gateway 
            initiated ServiceChange command message.

            The value of the object cannot be modified if
            the entry is active."
    DEFVAL          { 2 } 
    ::= { cmedxGatewayConfigEntry 25 }

cmedxGatewayMaxReplyMsgSize OBJECT-TYPE
    SYNTAX          Unsigned32 (1..4096 )
    UNITS           "Kbyte"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the maximum message size on
            this gateway link for a H248 transaction containing
            the media gateway reply messages to MGC. 
            For example, this object would limit the size of a
            H248 transaction containing the media gateway 
            reply message to the MGC initiated AuditValue command. 

            The value of the object cannot be modified if
            the entry is active."
    DEFVAL          { 250 } 
    ::= { cmedxGatewayConfigEntry 26 }

cmedxGatewaySctpAssocId OBJECT-TYPE
    SYNTAX          Unsigned32 (0..255 )
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object specifies the SCTP association ID associated
            with the H.248 association. This SCTP association ID 
            is the index (cSctpAssocId) of the entry in cSctpAssocTable.
            If the SCTP ID value is 0, it indicates no SCTP association." 
    ::= { cmedxGatewayConfigEntry 27 }

cmedxGatewaySrvChgProfile OBJECT-TYPE
    SYNTAX          SnmpAdminString (SIZE  (1..16))
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the profile name used in the profile
            parameter of ServiceChange message to specify the attributes
            and behaviors of the media gateway."
    DEFVAL          { "CISCO_TGW" } 
    ::= { cmedxGatewayConfigEntry 28 }

cmedxGatewaySrvChgProfileVer OBJECT-TYPE
    SYNTAX          Unsigned32 (1..99 )
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the version of the profile indicated
            in cmedxGatewaySrvChgProfile."
    DEFVAL          { 1 } 
    ::= { cmedxGatewayConfigEntry 29 }

cmedxGatewayMsgTokenType OBJECT-TYPE
    SYNTAX          INTEGER  {
                        shortFormat(1),
                        longFormat(2)
                    }
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the H248 message is in short formatted
            PDU or long formatted PDU."
    REFERENCE       "Annex B of H.248.1"
    DEFVAL          { shortFormat } 
    ::= { cmedxGatewayConfigEntry 30 }

cmedxGatewayMgProvisionRspTime OBJECT-TYPE
    SYNTAX          Unsigned32 (0..65535 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the time within which to expect a
            Pending Response if a transaction cannot be completed in
            the media gateway and in the MGCs of the media gateway 
            link.

            The value of this object should be greater than the value 
            of cmedxGatewayMgExecTime."
    REFERENCE       "Annex E.2 of H.248.1 version 2"
    DEFVAL          { 3000 } 
    ::= { cmedxGatewayConfigEntry 31 }

cmedxGatewayMgcProvisionRspTime OBJECT-TYPE
    SYNTAX          Unsigned32 (0..65535 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the time within which to expect a
            Pending Response from the MGC if a transaction cannot be 
            completed.

            The value of this object should be greater than the value
            of cmedxGatewayMgcExecTime."
    REFERENCE       "Annex E.2 of H.248.1 version 2"
    DEFVAL          { 3000 } 
    ::= { cmedxGatewayConfigEntry 32 }

cmedxGatewayMgOrigPendLimit OBJECT-TYPE
    SYNTAX          Unsigned32 (0..65535 )
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the number of TransactionPendings
            that MG will send.  Once this limit is exceeded, MG will
            send a TransactionReply with Error 506."
    REFERENCE       "Annex E.2 of H.248.1 version 2"
    DEFVAL          { 3 } 
    ::= { cmedxGatewayConfigEntry 33 }

cmedxGatewayMgcOrigPendLimit OBJECT-TYPE
    SYNTAX          Unsigned32 (0..65535 )
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the number of TransactionPendings
            that MG expects to receive.  Once this limit is exceeded, 
            MG will assume a TransactionReply with Error 506."
    REFERENCE       "Annex E.2 of H.248.1 version 2"
    DEFVAL          { 3 } 
    ::= { cmedxGatewayConfigEntry 34 }

cmedxGatewayDomainName OBJECT-TYPE
    SYNTAX          SnmpAdminString (SIZE  (0..255))
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the unique domain name to be
            used for each gateway link. This object is relevant    
            only if cmedxGatewayHeaderAddrType is set to 'dns'.
            The agent won't allow any attempt to set this value 
            for other address types. This domain name is expected
            to be resolved to a valid IP address through the use of
            a DNS located in the network. The default value of this 
            object is NULL string."
    DEFVAL          { "" } 
    ::= { cmedxGatewayConfigEntry 35 }

cmedxGatewayCmbDnAndPortInMID OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies whether the MID should be a
            combination of the transport port number and the  
            domain name represented by cmedGatewayPort and  
            cmedxGatewayDomainName respectively, when   
            cmedxGatewayHeaderAddrType is 'dns' .    

            A value of 'true' indicates that the MID will be a  
            combination of the domain name and the transport port  
            number.  

            A value of 'false' indicates that MID will contain  
            only the domain name and not the port number.    

            The agent won't allow any attempt to set this object  
            for other address types. "
    REFERENCE
            "(1) Annex B.2 of H.248.1 version 2
                     (2) cmedGatewayPort, CISCO-IETF-MEGACO-MIB. "
    DEFVAL          { true } 
    ::= { cmedxGatewayConfigEntry 36 }
 

-- *********************************************************************

-- cmedxTerminationTypeTable

-- *********************************************************************

cmedxTerminationTypeTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxTerminationTypeEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This table defines the attributes of a termination type
            for a group of ephemeral terminations."
    ::= { cmedxConfig 2 }

cmedxTerminationTypeEntry OBJECT-TYPE
    SYNTAX          CmedxTerminationTypeEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "Each entry represents one termination type for a group
            of ephemeral terminations in H.248.
            When creating an entry, the object cmedxTermType have to be 
            provided."
    INDEX           {
                        cmedGatewayId,
                        cmedxTermTypeId
                    } 
    ::= { cmedxTerminationTypeTable 1 }

CmedxTerminationTypeEntry ::= SEQUENCE {
        cmedxTermTypeId        Unsigned32,
        cmedxTermType          INTEGER ,
        cmedxTermTypeProfileId CCallControlProfileIndexOrZero,
        cmedxTermTypePkgIds    CH248Packages,
        cmedxTermTypeRowStatus RowStatus
}

cmedxTermTypeId OBJECT-TYPE
    SYNTAX          Unsigned32 (1..65535 )
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "An unique identification number that is assigned to
            the termination type by the manager" 
    ::= { cmedxTerminationTypeEntry 1 }

cmedxTermType OBJECT-TYPE
    SYNTAX          INTEGER  {
                        unknown(1),
                        scn(2),
                        pdnRtp(3),
                        pdnAtmAal1(4),
                        pdnAtmAal2(5)
                    }
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the type of a group of ephemeral
            terminations.
                unknown    (1) - none of the types listed below. 
                scn        (2) - SCN/DS terminations
                pdnRtp     (3) - PDN terminations of RTP type.
                pdnAtmAal1 (4) - PDN terminations of ATM type with
                                 AAL1 adaptation layer.
                pdnAtmAal2 (5) - PDN terminations of ATM type with
                                 AAL2 adaptation layer.
            If the value of this object is set to scn(2) or pdnRtp(3),
            the value of cmedxProfileAtmAalType for the profile of this
            termination type should be other(1).
            If the value of this object is set to pdnAtmAal1(4),
            the value of cmedxProfileAtmAalType for the profile of this
            termination type should be aal1(2), aal1Sdt(3), or 
            aal1Udt(4).
            If the value of this object is set to pdnAtmAal2(5),
            the value of cmedxProfileAtmAalType for the profile of this
            termination type should be aal2(5)."
    DEFVAL          { pdnRtp } 
    ::= { cmedxTerminationTypeEntry 2 }

cmedxTermTypeProfileId OBJECT-TYPE
    SYNTAX          CCallControlProfileIndexOrZero
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "The property profile identifier with which the terminations
            within this termination type will be associated."
    DEFVAL          { 0 } 
    ::= { cmedxTerminationTypeEntry 3 }

cmedxTermTypePkgIds OBJECT-TYPE
    SYNTAX          CH248Packages
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "The H.248 packages applied to this termination type." 
    ::= { cmedxTerminationTypeEntry 4 }

cmedxTermTypeRowStatus OBJECT-TYPE
    SYNTAX          RowStatus
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object is used to create new rows, modify existing rows
            and to delete existing rows." 
    ::= { cmedxTerminationTypeEntry 5 }
 

-- *********************************************************************

-- cmedxProfileTable

-- *********************************************************************

cmedxProfileTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxProfileEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This table contains a list of the configurable
            properties in the H.248 profile supported in 
            a media gateway.  
            A property profile can be applied to a termination,
            a group of termination, or a termination type."
    ::= { cmedxConfig 3 }

cmedxProfileEntry OBJECT-TYPE
    SYNTAX          CmedxProfileEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "Each entry represents all possible configurable
            properties supported by Cisco media gateway
            in an H.248 profile."
    INDEX           {
                        cmedGatewayId,
                        cmedxProfileIndex
                    } 
    ::= { cmedxProfileTable 1 }

CmedxProfileEntry ::= SEQUENCE {
        cmedxProfileIndex                CCallControlProfileIndex,
        cmedxProfilePlayCpToneInterDur   Unsigned32,
        cmedxProfileDtmfDigitOnDur       Unsigned32,
        cmedxProfileDtmfPauseDur         Unsigned32,
        cmedxProfileCot1Frequency        Unsigned32,
        cmedxProfileCot2Frequency        Unsigned32,
        cmedxProfileInitiateCotDur       Unsigned32,
        cmedxProfileRespCotMethod        INTEGER ,
        cmedxProfileDetectLongCpToneDur  Unsigned32,
        cmedxProfileDetectLongDigitDur   Unsigned32,
        cmedxProfileEchoCancelEnabled    TruthValue,
        cmedxProfileEchoCancelTail       INTEGER ,
        cmedxProfileInGainControl        Integer32,
        cmedxProfileOutAttnControl       Unsigned32,
        cmedxProfileVoIpVadEnabled       TruthValue,
        cmedxProfileVoIpVadTimer         Unsigned32,
        cmedxProfileVoAal2VadTimer       Unsigned32,
        cmedxProfileAtmBearerType        INTEGER ,
        cmedxProfileAtmAalPartialFill    Unsigned32,
        cmedxProfileAtmAalType           INTEGER ,
        cmedxProfileSuppressBearerDigit  TruthValue,
        cmedxProfileRowStatus            RowStatus,
        cmedxProfileOriginatingCotTx     CMedxCotTones,
        cmedxProfileOriginatingCotRx     CMedxCotTones,
        cmedxProfileTerminatingCotTx     CMedxCotTones,
        cmedxProfileTerminatingCotRx     CMedxCotTones,
        cmedxProfileComfortNoiseGenerate INTEGER 
}

cmedxProfileIndex OBJECT-TYPE
    SYNTAX          CCallControlProfileIndex
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This object uniquely identifies the H.248 profile." 
    ::= { cmedxProfileEntry 1 }

cmedxProfilePlayCpToneInterDur OBJECT-TYPE
    SYNTAX          Unsigned32 (0..4294967295 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the duration for playing
            a list of call progressing tones between two call 
            progressing signals.
            The value of 0 indicates there is no wait between 
            two call progressing signals."
    REFERENCE
            "H.248 Gateway Control Protocol,  Version 2
                     Call Progress Tones Generator Package (CG)."
    DEFVAL          { 60 } 
    ::= { cmedxProfileEntry 2 }

cmedxProfileDtmfDigitOnDur OBJECT-TYPE
    SYNTAX          Unsigned32 (40..4294967295 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the duration of the active DTMF
            digit during DTMF playout from the gateway. 
            A complete DTMF digit is characterized by DTMF on 
            with duration specified by this object followed by a 
            pause (signal off) duration specified by the object
            cmedxProfileDtmfPauseDuration."
    REFERENCE       "Q.23, Q.24, EIA/TIA-464"
    DEFVAL          { 100 } 
    ::= { cmedxProfileEntry 3 }

cmedxProfileDtmfPauseDur OBJECT-TYPE
    SYNTAX          Unsigned32 (40..4294967295 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the duration of the pause after an
            active DTMF digit during DTMF playout from the gateway. 
            For playout of multiple DTMF digits, the sum of the 
            digit-on and pause (signaling velocity) should not be
            shorter than the time specified in Q.23, Q.24 and 
            EIA/TIA-464. For example, 93ms/digit for AT&T,
            120ms/digit for NTT, 100ms/digit for Danish 
            Administration."
    REFERENCE       "Q.23, Q.24, EIA/TIA-464"
    DEFVAL          { 100 } 
    ::= { cmedxProfileEntry 4 }

cmedxProfileCot1Frequency OBJECT-TYPE
    SYNTAX          Unsigned32 (1..4000 )
    UNITS           "Hz"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the tone frequency to be
            transmit between gateways in the continuity test."
    DEFVAL          { 2010 } 
    ::= { cmedxProfileEntry 5 }

cmedxProfileCot2Frequency OBJECT-TYPE
    SYNTAX          Unsigned32 (1..4000 )
    UNITS           "Hz"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the tone frequency to be
            received between gateways in the continuity test."
    DEFVAL          { 1780 } 
    ::= { cmedxProfileEntry 6 }

cmedxProfileInitiateCotDur OBJECT-TYPE
    SYNTAX          Unsigned32 (0..4294967295 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the duration for the continuity
            test tone to be played when the gateway initiates a COT.
            The value of 0 indicates that the tone will be played 
            infinitely unless interrupted."
    REFERENCE
            "H.248 Gateway Control Protocol,  Version 2
                     Basic Continuity Package (CT)."
    DEFVAL          { 500 } 
    ::= { cmedxProfileEntry 7 }

cmedxProfileRespCotMethod OBJECT-TYPE
    SYNTAX          INTEGER  {
                        loopback(1),
                        transponder(2)
                    }
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the method for responding to COT
            (Continuity Test Tone) when the gateway detects a  
            the continuity test signal.
               loopback    (1) - The gateway loops back the received 
                                 continuity test signal.
               transponder (2) - The gateway responds with another 
                                 continuity test signal upon detecting
                                 a continuity test signal.
            When this object is set to loopback(1), the originating
            gateway transmits the frequency specified in the value of
            cmedxProfileCot1Frequency, the terminating gateway loops
            back whatever it receives. 
            When this object is set to transponder(2), the originating
            gateway transmit the frequency specified in the value of
            cmedxProfileCot1Frequency, and the terminating gateway 
            responds the frequency specified in the value of
            cmedxProfileCot2Frequency."
    REFERENCE
            "H.248 Gateway Control Protocol,  Version 2
                     Basic Continuity Package (CT)."
    DEFVAL          { loopback } 
    ::= { cmedxProfileEntry 8 }

cmedxProfileDetectLongCpToneDur OBJECT-TYPE
    SYNTAX          Unsigned32 (0..4294967295 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the duration for detecting a
            long call progressing tone."
    REFERENCE
            "H.248 Gateway Control Protocol,  Version 2
                     Call Progress Tones Detection Package (CD)."
    DEFVAL          { 7000 } 
    ::= { cmedxProfileEntry 9 }

cmedxProfileDetectLongDigitDur OBJECT-TYPE
    SYNTAX          Unsigned32 (0..4294967295 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the duration for detecting a
            long digit tone signal."
    REFERENCE
            "H.248 Gateway Control Protocol,  Version 2
                     DTMF Detection Package (DD)."
    DEFVAL          { 7000 } 
    ::= { cmedxProfileEntry 10 }

cmedxProfileEchoCancelEnabled OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies whether or not the Echo
            Cancellation is enabled or not."
    REFERENCE
            "H.248 Gateway Control Protocol,  Version 2
                     TDM Circuit Package (TDMC)."
    DEFVAL          { true } 
    ::= { cmedxProfileEntry 11 }

cmedxProfileEchoCancelTail OBJECT-TYPE
    SYNTAX          INTEGER  {
                        echoCanceller8ms(1),
                        echoCanceller16ms(2),
                        echoCanceller24ms(3),
                        echoCanceller32ms(4),
                        echoCanceller64ms(5),
                        echoCanceller128ms(6)
                    }
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the Echo Canceler coverage.
            This object is valid if the cmedxProfileEchoCancelEnabled
            object is 'true'.
            echoCanceller8ms  -  8 ms echo canceler coverage.
            echoCanceller16ms - 16 ms echo canceler coverage.
            echoCanceller24ms - 24 ms echo canceler coverage.
            echoCanceller32ms - 32 ms echo canceler coverage.
            echoCanceller64ms - 64 ms echo canceler coverage.
            echoCanceller128ms- 128 ms echo canceler coverage."
    DEFVAL          { echoCanceller8ms } 
    ::= { cmedxProfileEntry 12 }

cmedxProfileInGainControl OBJECT-TYPE
    SYNTAX          Integer32 (-6..14 )
    UNITS           "dB"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object contains the amount of gain inserted at the
            receiver side of the interface. The input gain settings
            only define a gain/loss relative to the 0 dB setting.
            The absolute loss at the 0 dB setting could be
            implementation dependent based on the desired network
            loss plan."
    REFERENCE
            "H.248 Gateway Control Protocol,  Version 2
                     TDM Circuit Package (TDMC)."
    DEFVAL          { 0 } 
    ::= { cmedxProfileEntry 13 }

cmedxProfileOutAttnControl OBJECT-TYPE
    SYNTAX          Unsigned32 (0..14 )
    UNITS           "dB"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object contains the amount of attenuation inserted
            at the transmit side of the interface.
            The output attenuation settings only define a loss
            relative to the 0 dB setting.
            The absolute loss at the 0 dB setting could be
            implementation dependent based on the desired network
            loss plan."
    DEFVAL          { 0 } 
    ::= { cmedxProfileEntry 14 }

cmedxProfileVoIpVadEnabled OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies VAD (Voice Activity Detection)
            is enabled for the compression DSPs of this interface
            when the application is VoIP."
    DEFVAL          { true } 
    ::= { cmedxProfileEntry 15 }

cmedxProfileVoIpVadTimer OBJECT-TYPE
    SYNTAX          Unsigned32 (0..4294967295 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the hangover time for VAD in the
            VoIP application.
            Once the voice inactivity is detected, the media gateway
            waits for the duration of this value before activating 
            silence suppression. 
            This object is not applicable if cmedxProfileVoIpVadEnabled
            is set to 'false'."
    DEFVAL          { 100 } 
    ::= { cmedxProfileEntry 16 }

cmedxProfileVoAal2VadTimer OBJECT-TYPE
    SYNTAX          Unsigned32 (0..4294967295 )
    UNITS           "milliseconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the hangover time for VAD in the
            VoATM over AAL2 application.
            Once the voice inactivity is detected, the media gateway
            waits for the duration of this value before activating 
            silence suppression. 
            This object is not applicable if cvapAal2ProfVad 
            is set to 'vadOff'."
    DEFVAL          { 100 } 
    ::= { cmedxProfileEntry 17 }

cmedxProfileAtmBearerType OBJECT-TYPE
    SYNTAX          INTEGER  {
                        bearerSvc(1),
                        bearerPvc(2)
                    }
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies ATM bearer type.
            bearerSvc (1) - the ATM bearer type is SVC (Switched
                            Virtual Circuit).
            bearerPvc (1) - the ATM bearer type is PVC (Permanent
                            Virtual Circuit)."
    DEFVAL          { bearerSvc } 
    ::= { cmedxProfileEntry 18 }

cmedxProfileAtmAalPartialFill OBJECT-TYPE
    SYNTAX          Unsigned32 (1..48 )
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the fill level of cells in case of
            AAL adaptation .
            The value of this object will be used if the MGC does
            not specify partial fill in the commands.
            ATM cell size is 53 bytes, 5 bytes for header, 48 bytes
            for data. If the data are not enough to fill 48 bytes of one
            ATM cell, the system can fill in the value of this object to
            the padding bytes."
    DEFVAL          { 47 } 
    ::= { cmedxProfileEntry 19 }

cmedxProfileAtmAalType OBJECT-TYPE
    SYNTAX          INTEGER  {
                        other(1),
                        aal1(2),
                        aal1Sdt(3),
                        aal1Udt(4),
                        aal2(5)
                    }
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the adaptation layer of ATM.
            other   (1) - None of the types listed below.
            aal1    (2) - ATM AAL1 adaptation layer
            aal1Sdt (3) - ATM AAL1 with SDT (Structured Data 
                          Transfer)
            aal1Udt (4) - ATM AAL1 with UDT (Unstructured Data 
                          Transfer). 
            aal2    (5) - ATM AAL2 adaptation layer."
    DEFVAL          { aal1Sdt } 
    ::= { cmedxProfileEntry 20 }

cmedxProfileSuppressBearerDigit OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object controls if the digits should be suppressed
            from voice media stream. When MGC has requested digits,
            if this object is set to 'true', the digits will be 
            reported to MGC only, the digits will not be sent as
            regular voice or peer-to-peer packets in the bearer.

            When MGC has requested digits, if this object is set to
            'false', the digits will be reported to MGC as well as 
            be sent in the bearer according to the value of 
            cvapCodecConfigDtmfRelay in cvapCodecConfigTable.

            When MGC has not requested digits, this object will be
            ignored. The digits will be sent in the bearer according
            to the value of cvapCodecConfigDtmfRelay in 
            cvapCodecConfigTable."
    DEFVAL          { false } 
    ::= { cmedxProfileEntry 21 }

cmedxProfileRowStatus OBJECT-TYPE
    SYNTAX          RowStatus
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "When an entry is created, at least one of the objects
            in the entry has to be provided and the default value
            will be assigned to the rest of the objects." 
    ::= { cmedxProfileEntry 22 }

cmedxProfileOriginatingCotTx OBJECT-TYPE
    SYNTAX          CMedxCotTones
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the COT tone to be transmitted
            from originating gateway in the continuity test." 
    ::= { cmedxProfileEntry 23 }

cmedxProfileOriginatingCotRx OBJECT-TYPE
    SYNTAX          CMedxCotTones
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the COT tone to be received
            in originating gateway in the continuity test." 
    ::= { cmedxProfileEntry 24 }

cmedxProfileTerminatingCotTx OBJECT-TYPE
    SYNTAX          CMedxCotTones
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the COT tone to be transmitted
            from terminating gateway in the continuity test." 
    ::= { cmedxProfileEntry 25 }

cmedxProfileTerminatingCotRx OBJECT-TYPE
    SYNTAX          CMedxCotTones
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the COT tone to be received
            in terminating gateway in the continuity test." 
    ::= { cmedxProfileEntry 26 }

cmedxProfileComfortNoiseGenerate OBJECT-TYPE
    SYNTAX          INTEGER  {
                        none(1),
                        simple(2),
                        g711A2(3)
                    }
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
            "This object specifies the type of comfort noise generation:

            (1) none: No comfort noise generation applied
            (2) simple: Cisco Proprietary comfort noise generation
            (3) g711A2: ITU G.711 Appendix II compliant

            "
    DEFVAL          { simple } 
    ::= { cmedxProfileEntry 27 }
 

-- *********************************************************************

-- cmedxCallReduceControlTable

-- *********************************************************************

cmedxCallReduceControlTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxCallReduceControlEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "The MIB objects in this table are used to control
            the rate at which call attempts are made by Media 
            gateway controller on this Media Gateway.
            "
    ::= { cmedxConfig 4 }

cmedxCallReduceControlEntry OBJECT-TYPE
    SYNTAX          CmedxCallReduceControlEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "An entry in this table contains the control parameters that
            indicate the frequency and number of notifications sent to
            MGC in the event congestion is detected on MG.
            "
    INDEX           { cmedGatewayId } 
    ::= { cmedxCallReduceControlTable 1 }

CmedxCallReduceControlEntry ::= SEQUENCE {
        cmedxCallCongEnabled     TruthValue,
        cmedxCallRenotifInterval Unsigned32,
        cmedxCRRNumOfLevel       Unsigned32,
        cmedxCurrentCRR          Unsigned32,
        cmedxCrrNotifyState      TruthValue,
        cmedxCrrNotifyEnabled    OCTET STRING,
        cmedxCurrentCallState    INTEGER 
}

cmedxCallCongEnabled OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
            "This object controls if the H.248 congestion package
            (H.248.10) and its associated features should be enabled
            for the media gateway.

            If this object is set to 'false', then the following MIB
            objects and MIB table will be ignored:
                cmedxCallRenotifInterval
                cmedxCRRNumOfLevel
                cmedxCurrentCRR
                cmedxCrrNotifyState
                cmedxCrrNotifyEnabled
                cmedxCallReduceLevelTable. "
    DEFVAL          { false } 
    ::= { cmedxCallReduceControlEntry 1 }

cmedxCallRenotifInterval OBJECT-TYPE
    SYNTAX          Unsigned32 (0..100 )
    UNITS           "seconds"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
            "This object specifies the interval of the congestion
            renotification from the media gateway to the MGC.

            In the event of congestion on the Media Gateway, gateway 
            generates an event towards MGC. Using this message, MG 
            requests percentage reduction in the rate of calls that 
            MGC is attempting towards MG.
            After sending this indication, MG starts a timer based on 
            'cmedxCallRenotifInterval'. At this timer expires, MG will 
            re-send the message to MGC indicating that it is still in 
            congested state. If MGC does not receive another 
            notification, MGC will resume to the original call rate.
            If MGC requires re-notifications, it is user's 
            responsibility to set the value of this MIB object on 
            MG appropriately.
            The value of this object should be set such that it factors 
            into the network delay and re-notification timer 
            (similar to this MIB object) configured on MGC.
            The zero means MGC does not require re-notifications, 
            MGC will keep CallReduceRate until receive another 
            notification from the Media Gateway. "
    DEFVAL          { 0 } 
    ::= { cmedxCallReduceControlEntry 2 }

cmedxCRRNumOfLevel OBJECT-TYPE
    SYNTAX          Unsigned32 (1..16 )
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
            "This objects specifies the number of level corresponding to
            which a different call reduction rate notification is 
            generated towards MGC. 

            Each level has a different call reduction rate, the CRR 
            information is stored on cmedxCallReduceLevelTabl.
            And The table size equals to the value of 
            'cmedxCRRNumOfLevel'. "
    DEFVAL          { 6 } 
    ::= { cmedxCallReduceControlEntry 3 }

cmedxCurrentCRR OBJECT-TYPE
    SYNTAX          Unsigned32 (0..100 )
    UNITS           "percent"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object indicates the current percentage reduction in
            the rate of calls that MGC is attempting towards MG.
            " 
    ::= { cmedxCallReduceControlEntry 4 }

cmedxCrrNotifyState OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object indicates the current gateway congestion
            notification state.
            The value of 'true' means the gateway will notify
            MGC when the gateway is congested.
            The value of 'false' means the gateway won't notify
            MGC when the gateway is congested.
            This object is 'true' when cmedxCallCongEnabled is 
            set to 'true' and at least one of MGCs enabled the
            CRR notification (cmedxCrrNotifyEnabled is not 0)." 
    ::= { cmedxCallReduceControlEntry 5 }

cmedxCrrNotifyEnabled OBJECT-TYPE
    SYNTAX          OCTET STRING (SIZE  (4))
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object indicates the bit map of the H248 association
            index (cmedGatewayLinkId) in which the gateway congestion 
            notification is enabled.
            The MSB (most significant bit) is the association index 1.
            A 1-bit indicates the gateway congestion notification is
            enabled in this H248 association. A 0-bit indicates it is
            disabled." 
    ::= { cmedxCallReduceControlEntry 6 }

cmedxCurrentCallState OBJECT-TYPE
    SYNTAX          INTEGER  {
                        acceptCall(1),
                        dropCall(2)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object indicates the state of the gateway in
            accepting the incoming new call.

            acceptCall - the incoming new call will be processed.
            dropCall   - the incoming new call will be droped due
                         to the resources congested." 
    ::= { cmedxCallReduceControlEntry 7 }
 

-- *********************************************************************

-- cmedxCallReduceLevelTable

-- *********************************************************************

cmedxCallReduceLevelTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxCallReduceLevelEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "The table presents mapping between a level and corresponding
            call reduction rate."
    ::= { cmedxConfig 5 }

cmedxCallReduceLevelEntry OBJECT-TYPE
    SYNTAX          CmedxCallReduceLevelEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "The number of entry on this table is determined by the MIB
            object 'cmedxCRRNumOfLevel'."
    INDEX           {
                        cmedGatewayId,
                        cmedxCallReduceLevelNum
                    } 
    ::= { cmedxCallReduceLevelTable 1 }

CmedxCallReduceLevelEntry ::= SEQUENCE {
        cmedxCallReduceLevelNum Unsigned32,
        cmedxCallReduceRate     Unsigned32
}

cmedxCallReduceLevelNum OBJECT-TYPE
    SYNTAX          Unsigned32 (1..16 )
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "The index starts from 1, and the maximum index equals to
            'cmedxCRRNumOfLevel'." 
    ::= { cmedxCallReduceLevelEntry 1 }

cmedxCallReduceRate OBJECT-TYPE
    SYNTAX          Unsigned32 (1..100 )
    UNITS           "percent"
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
            "This object indicates call reduction rate (CRR) for a given
            call reduce rate level. 

            The default value of this object is based on the formula:
               level 1: 100 
               other level: 100 - ((80/(nol - 1)) * (level - 1))

            Here: 
               nol  : number of level(cmedxCRRNumOfLevel)
               level: specific level (cmedxCallReduceLevelNum)

            User can configure this object, the rule is:
               level x > level x+1 " 
    ::= { cmedxCallReduceLevelEntry 2 }
 

-- *********************************************************************

-- cmedxOverloadControlTable

-- *********************************************************************

cmedxOverloadControlTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxOverloadControlEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This table is used to configure the media gateway
            overload control parameters specified in H.248.11 package."
    ::= { cmedxConfig 7 }

cmedxOverloadControlEntry OBJECT-TYPE
    SYNTAX          CmedxOverloadControlEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "An entry in this table contains the overload control
            parameters of the media gateway."
    INDEX           { cmedGatewayId } 
    ::= { cmedxOverloadControlTable 1 }

CmedxOverloadControlEntry ::= SEQUENCE {
        cmedxOverloadControlEnabled TruthValue,
        cmedxOverloadNotifyState    TruthValue,
        cmedxOverloadNotifyEnabled  OCTET STRING
}

cmedxOverloadControlEnabled OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
            "This object controls if the H.248 overload package
            (H.248.11) and its associated features should be enabled
            for the media gateway.

            If this object is set to 'false', then the following MIB
            objects and MIB table will be ignored:
                cmedxOverloadNotifyState
                cmedxOverloadNotifyEnabled."
    DEFVAL          { true } 
    ::= { cmedxOverloadControlEntry 1 }

cmedxOverloadNotifyState OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object indicates the current gateway overload
            notification state.
            The value of 'true' means the gateway will notify
            MGC when the gateway is overloaded.
            The value of 'false' means the gateway won't notify
            MGC when the gateway is overloaded. 
            This object is 'true' when cmedxOverloadControlEnabled
            is set to 'true' and at least one of MGCs enabled 
            gateway overload notification (cmedxOverloadNotifyEnabled
            is not 0)." 
    ::= { cmedxOverloadControlEntry 2 }

cmedxOverloadNotifyEnabled OBJECT-TYPE
    SYNTAX          OCTET STRING (SIZE  (4))
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object indicates the bit map of the H248 association
            index (cmedGatewayLinkId) in which the gateway overload 
            notification is enabled.
            The MSB (most significant bit) is the association index 1.
            A 1-bit indicates the gateway overload notification is
            enabled in this H248 association. A 0-bit indicates it is
            disabled." 
    ::= { cmedxOverloadControlEntry 3 }
 


cmedxCodecNegotiationTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxCodecNegotiationEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This table contains configuration information for different
            type of CODEC negotiation of calls which include voice call 
            over adaptation layer AAL1 and AAL5.
            If the value lclLcoRcd(5), lclRcdLco(6) of 
            cvapCodecNegotiationOption is used as CODEC negotiation 
            option, the CODEC list configuration information in this   
            table will be used for CODEC negotiation."
    ::= { cmedxConfig 6 }

cmedxCodecNegotiationEntry OBJECT-TYPE
    SYNTAX          CmedxCodecNegotiationEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "An entry represents a CODEC rate supported for VoIP or
            VoATM with AAL1 or AAL5 application in the media gateway. 
            A list of entries for all CODEC types supported in the media
            gateway are created by the agent when a cmedxProfileEntry
            is created."
    INDEX           {
                        cmedGatewayId,
                        cmedxProfileIndex,
                        cmedxCodecNegotiationCodec
                    } 
    ::= { cmedxCodecNegotiationTable 1 }

CmedxCodecNegotiationEntry ::= SEQUENCE {
        cmedxCodecNegotiationCodec      CvcSpeechCoderRate,
        cmedxCodecNegotiationPreference Unsigned32
}

cmedxCodecNegotiationCodec OBJECT-TYPE
    SYNTAX          CvcSpeechCoderRate
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This object specifies the CODEC to be used in this
            profile." 
    ::= { cmedxCodecNegotiationEntry 1 }

cmedxCodecNegotiationPreference OBJECT-TYPE
    SYNTAX          Unsigned32 (0..255 )
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
            "This object specified the preference configured by the
            user for each CODEC. Lower the number, higher the 
            preference of the CODEC.

            If this object is set to 0, the corresponding CODEC will 
            not be used in coded negotiation procedure.           

            Initially, if the value of cmedxCodecNegotiationCodec is
            g711u, this object is set to 1, else this object is set to 0.

            For CODECs having the same preference, the entry with the 
            lower index has higher precedence."
    DEFVAL          { 1 } 
    ::= { cmedxCodecNegotiationEntry 2 }
 

-- *****************************************************************

-- cmedxGatewayStatsTable

-- This table is extended from cmedGatewayStatsTable which
-- contains the control protocol related statistics of
-- the media gateway link.

-- *****************************************************************

cmedxGatewayStatsTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxGatewayStatsEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This table is extended from cmedGatewayStatsTable which
            contains additional control protocol related statistics of
            the media gateway link."
    ::= { cmedxStats 1 }

cmedxGatewayStatsEntry OBJECT-TYPE
    SYNTAX          CmedxGatewayStatsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "Entry holding statistics about a group of
            media Gateway/signaling link pair"
    AUGMENTS           { cmedGatewayStatsEntry  } 
 
    ::= { cmedxGatewayStatsTable 1 }

CmedxGatewayStatsEntry ::= SEQUENCE {
        cmedxGatewayLastEvent Unsigned32
}

cmedxGatewayLastEvent OBJECT-TYPE
    SYNTAX          Unsigned32 (1..1000 )
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The event code of the last event occurred on the link." 
    ::= { cmedxGatewayStatsEntry 1 }
 

-- ********************************************************************

-- cmedxCommandStatsTable

-- ********************************************************************

cmedxCommandStatsTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxCommandStatsEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This table provides the H.248 Command related statistics
            for the media gateway link.

            The H.248 protocol provides commands for manipulating the
            logical entities of the protocol connection model, 
            Contexts and Terminations.
            For example, Commands exist to add Terminations to a Context, 
            modify Terminations, subtract Terminations from a Context,
            and audit properties of Contexts or Terminations.

            Most commands are for the specific use of the Media Gateway
            Controller (MGC) as command initiator in controlling Media 
            Gateways (MG) as command responders.  The exceptions are the 
            Notify and ServiceChange commands: 
            Notify is sent from Media Gateway to Media Gateway Controller, 
            and ServiceChange may be sent by either entity."
    ::= { cmedxStats 2 }

cmedxCommandStatsEntry OBJECT-TYPE
    SYNTAX          CmedxCommandStatsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "The system creates one entry for each media gateway link
            when it is created."
    INDEX           {
                        cmedGatewayId,
                        cmedGatewayLinkId
                    } 
    ::= { cmedxCommandStatsTable 1 }

CmedxCommandStatsEntry ::= SEQUENCE {
        cmedxCmdNumAddFails              Counter32,
        cmedxCmdNumAddSucceeds           Counter32,
        cmedxCmdNumSubtractFails         Counter32,
        cmedxCmdNumSubtractSucceeds      Counter32,
        cmedxCmdNumMoveFails             Counter32,
        cmedxCmdNumMoveSucceeds          Counter32,
        cmedxCmdNumModifyFails           Counter32,
        cmedxCmdNumModifySucceeds        Counter32,
        cmedxCmdNumAuditValFails         Counter32,
        cmedxCmdNumAuditValSucceeds      Counter32,
        cmedxCmdNumAuditCapFails         Counter32,
        cmedxCmdNumAuditCapSucceeds      Counter32,
        cmedxCmdNumNotifyFails           Counter32,
        cmedxCmdNumNotifySucceeds        Counter32,
        cmedxCmdNumSrvChgFromMgcFails    Counter32,
        cmedxCmdNumSrvChgFromMgcSucceeds Counter32,
        cmedxCmdNumSrvChgFromMgFails     Counter32,
        cmedxCmdNumSrvChgFromMgSucceeds  Counter32,
        cmedxCmdTotalFails               Counter32,
        cmedxCmdTotalSucceeds            Counter32,
        cmedxCmdTotal                    Counter32,
        cmedxCmdNumAddPendings           Counter32,
        cmedxCmdNumSubtractPendings      Counter32,
        cmedxCmdNumMovePendings          Counter32,
        cmedxCmdNumModifyPendings        Counter32,
        cmedxCmdNumAuditValPendings      Counter32,
        cmedxCmdNumAuditCapPendings      Counter32,
        cmedxCmdNumNotifyPendings        Counter32,
        cmedxCmdNumSrvChgFromMgcPendings Counter32,
        cmedxCmdNumSrvChgFromMgPendings  Counter32,
        cmedxCmdTotalPendings            Counter32
}

cmedxCmdNumAddFails OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative ADD commands failed in
            the media gateway link." 
    ::= { cmedxCommandStatsEntry 1 }

cmedxCmdNumAddSucceeds OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative ADD command succeeded
            in the media gateway link." 
    ::= { cmedxCommandStatsEntry 2 }

cmedxCmdNumSubtractFails OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative SUBTRACT commands failed
            in the media gateway link." 
    ::= { cmedxCommandStatsEntry 3 }

cmedxCmdNumSubtractSucceeds OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative SUBTRACT commands succeeded
            in the media gateway link." 
    ::= { cmedxCommandStatsEntry 4 }

cmedxCmdNumMoveFails OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative MOVE commands failed in
            the media gateway link." 
    ::= { cmedxCommandStatsEntry 5 }

cmedxCmdNumMoveSucceeds OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative MOVE commands succeeded
            in the media gateway link." 
    ::= { cmedxCommandStatsEntry 6 }

cmedxCmdNumModifyFails OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative MODIFY commands failed
            in the media gateway link." 
    ::= { cmedxCommandStatsEntry 7 }

cmedxCmdNumModifySucceeds OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative MODIFY commands succeeded
            in the media gateway link." 
    ::= { cmedxCommandStatsEntry 8 }

cmedxCmdNumAuditValFails OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative AUDIT VALUE commands failed
            in the media gateway link." 
    ::= { cmedxCommandStatsEntry 9 }

cmedxCmdNumAuditValSucceeds OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative AUDIT VALUE commands succeeded
            in the media gateway link." 
    ::= { cmedxCommandStatsEntry 10 }

cmedxCmdNumAuditCapFails OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative AUDIT CAPABILITY commands
            failed in the media gateway link." 
    ::= { cmedxCommandStatsEntry 11 }

cmedxCmdNumAuditCapSucceeds OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative AUDIT CAPABILITY commands
            succeeded in the media gateway link." 
    ::= { cmedxCommandStatsEntry 12 }

cmedxCmdNumNotifyFails OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative NOTIFY commands failed to
            respond from MGC." 
    ::= { cmedxCommandStatsEntry 13 }

cmedxCmdNumNotifySucceeds OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative NOTIFY commands successfully
            responded from the MGC." 
    ::= { cmedxCommandStatsEntry 14 }

cmedxCmdNumSrvChgFromMgcFails OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative ServiceChange commands from
            MGC to MG failed in the media gateway link." 
    ::= { cmedxCommandStatsEntry 15 }

cmedxCmdNumSrvChgFromMgcSucceeds OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative ServiceChange commands from
            MGC to MG succeeded in the media gateway link." 
    ::= { cmedxCommandStatsEntry 16 }

cmedxCmdNumSrvChgFromMgFails OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative ServiceChange commands from
            MG to MGC failed in MGC." 
    ::= { cmedxCommandStatsEntry 17 }

cmedxCmdNumSrvChgFromMgSucceeds OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative ServiceChange commands from MG
            to MGC succeeded in MGC." 
    ::= { cmedxCommandStatsEntry 18 }

cmedxCmdTotalFails OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of commands failed in the media gateway
            link.
            " 
    ::= { cmedxCommandStatsEntry 19 }

cmedxCmdTotalSucceeds OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of commands succeeded in the media gateway
            link.
            " 
    ::= { cmedxCommandStatsEntry 20 }

cmedxCmdTotal OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of failed and successful commands in the
            media gateway link.
            " 
    ::= { cmedxCommandStatsEntry 21 }

cmedxCmdNumAddPendings OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative ADD commands
            remain pending in the media gateway link.
            " 
    ::= { cmedxCommandStatsEntry 22 }

cmedxCmdNumSubtractPendings OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative SUBTRACT commands
            remain pending in the media gateway link.
            " 
    ::= { cmedxCommandStatsEntry 23 }

cmedxCmdNumMovePendings OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative MOVE commands
            remain pending in the media gateway link.
            " 
    ::= { cmedxCommandStatsEntry 24 }

cmedxCmdNumModifyPendings OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative MODIFY commands
            remain pending in the media gateway link.
            " 
    ::= { cmedxCommandStatsEntry 25 }

cmedxCmdNumAuditValPendings OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative AUDIT VALUE commands
            remain pending in the media gateway link.
            " 
    ::= { cmedxCommandStatsEntry 26 }

cmedxCmdNumAuditCapPendings OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative AUDIT CAPABILITY commands
            remain pending in the media gateway link." 
    ::= { cmedxCommandStatsEntry 27 }

cmedxCmdNumNotifyPendings OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative NOTIFY commands
            remain pending in response from MGC." 
    ::= { cmedxCommandStatsEntry 28 }

cmedxCmdNumSrvChgFromMgcPendings OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative ServiceChange commands from
            MGC to MG remain pending in the media gateway link." 
    ::= { cmedxCommandStatsEntry 29 }

cmedxCmdNumSrvChgFromMgPendings OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of cumulative ServiceChange commands from
            MG to MGC remain pending in MGC." 
    ::= { cmedxCommandStatsEntry 30 }

cmedxCmdTotalPendings OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of commands remain pending
            in the media gateway link.
            " 
    ::= { cmedxCommandStatsEntry 31 }
 

-- ********************************************************************

-- cmedxContextStatsTable

-- ********************************************************************

cmedxContextStatsTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxContextStatsEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This table provides the H.248 Context related statistics
            for the media gateway link."
    ::= { cmedxStats 3 }

cmedxContextStatsEntry OBJECT-TYPE
    SYNTAX          CmedxContextStatsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "The system creates one entry for each media gateway link
            when it is created."
    INDEX           {
                        cmedGatewayId,
                        cmedGatewayLinkId
                    } 
    ::= { cmedxContextStatsTable 1 }

CmedxContextStatsEntry ::= SEQUENCE {
        cmedxCntxNumActiveContexts     Gauge32,
        cmedxCntxPeakNumActiveContexts Gauge32,
        cmedxCntxNumContextAllocated   Counter32,
        cmedxCntxNumContextFreed       Counter32,
        cmedxCntxShortestContextLife   TimeTicks,
        cmedxCntxAverageContextLife    TimeTicks,
        cmedxCntxLongestContextLife    TimeTicks,
        cmedxCntxNumCntxMoreThan2Terms Gauge32
}

cmedxCntxNumActiveContexts OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The current number of active contexts in the media
            gateway link." 
    ::= { cmedxContextStatsEntry 1 }

cmedxCntxPeakNumActiveContexts OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Peak number of active contexts in the media gateway link." 
    ::= { cmedxContextStatsEntry 2 }

cmedxCntxNumContextAllocated OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of contexts has been allocated in
            the media gateway link." 
    ::= { cmedxContextStatsEntry 3 }

cmedxCntxNumContextFreed OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of contexts has been freed in the
            media gateway link." 
    ::= { cmedxContextStatsEntry 4 }

cmedxCntxShortestContextLife OBJECT-TYPE
    SYNTAX          TimeTicks
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The shortest life span for the contexts in the
            media gateway link." 
    ::= { cmedxContextStatsEntry 5 }

cmedxCntxAverageContextLife OBJECT-TYPE
    SYNTAX          TimeTicks
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The average life span for the contexts in the media
            gateway link." 
    ::= { cmedxContextStatsEntry 6 }

cmedxCntxLongestContextLife OBJECT-TYPE
    SYNTAX          TimeTicks
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The longest life span for the contexts in the media
            gateway link." 
    ::= { cmedxContextStatsEntry 7 }

cmedxCntxNumCntxMoreThan2Terms OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The number of contexts having more than 2 terminations
            in the media gateway link." 
    ::= { cmedxContextStatsEntry 8 }
 

-- *****************************************************************

-- cmedxPhysicalTermStatsTable

-- *****************************************************************

cmedxPhysicalTermStatsTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxPhysicalTermStatsEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This table contains statistics related to physical
            terminations in a media gateway."
    ::= { cmedxStats 4 }

cmedxPhysicalTermStatsEntry OBJECT-TYPE
    SYNTAX          CmedxPhysicalTermStatsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "Each entry contains the statistics for a physical
            termination in the media gateway."
    AUGMENTS           { cmedTerminationsEntry  } 
 
    ::= { cmedxPhysicalTermStatsTable 1 }

CmedxPhysicalTermStatsEntry ::= SEQUENCE {
        cmedxPhyTermStatsNumAdds     Counter32,
        cmedxPhyTermStatsNumFailures Counter32,
        cmedxPhyTermStatsOosFromMgcs Counter32,
        cmedxPhyTermStatsOosFromOams Counter32
}

cmedxPhyTermStatsNumAdds OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Number of total ADD commands on this physical
            termination." 
    ::= { cmedxPhysicalTermStatsEntry 1 }

cmedxPhyTermStatsNumFailures OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Number of total command failures on this
            physical termination." 
    ::= { cmedxPhysicalTermStatsEntry 2 }

cmedxPhyTermStatsOosFromMgcs OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Number of total out of service initiated from MGC on
            this physical termination." 
    ::= { cmedxPhysicalTermStatsEntry 3 }

cmedxPhyTermStatsOosFromOams OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Number of total out of service initiated from OAM
            (Operation Administration Management, either MG or NMS) 
            on this physical termination." 
    ::= { cmedxPhysicalTermStatsEntry 4 }
 

-- *****************************************************************

-- cmedxEphemeralTermStatsTable

-- *****************************************************************

cmedxEphemeralTermStatsTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxEphemeralTermStatsEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This table contains statistics related to ephemeral
            terminations."
    ::= { cmedxStats 5 }

cmedxEphemeralTermStatsEntry OBJECT-TYPE
    SYNTAX          CmedxEphemeralTermStatsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "Each entry contains the statistics of all ephemeral
            terminations for the termination type."
    INDEX           {
                        cmedGatewayId,
                        cmedxEphTermStatsType
                    } 
    ::= { cmedxEphemeralTermStatsTable 1 }

CmedxEphemeralTermStatsEntry ::= SEQUENCE {
        cmedxEphTermStatsType        INTEGER ,
        cmedxEphTermStatsNumAdds     Counter32,
        cmedxEphTermStatsNumFailures Counter32
}

cmedxEphTermStatsType OBJECT-TYPE
    SYNTAX          INTEGER  {
                        all(1),
                        scn(2),
                        pdnRtp(3),
                        pdnAtmAal1(4),
                        pdnAtmAal2(5)
                    }
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This object specifies the statistics of the termination type
            to be retrieved.
                all        (1) - Statistics for all ephemeral termination
                                 types.
                scn        (2) - Statistics for SCN/DS terminations
                pdnRtp     (3) - Statistics for PDN terminations of RTP
                                 type.
                pdnAtmAal1 (4) - Statistics for PDN terminations of 
                                 ATM type with AAL1 adaptation layer.
                pdnAtmAal2 (5) - Statistics for PDN terminations of
                                 ATM type with AAL2 adaptation layer." 
    ::= { cmedxEphemeralTermStatsEntry 1 }

cmedxEphTermStatsNumAdds OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Number of total ADD commands has been initiated
            on this termination type." 
    ::= { cmedxEphemeralTermStatsEntry 2 }

cmedxEphTermStatsNumFailures OBJECT-TYPE
    SYNTAX          Counter32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Number of total command failures on this
            termination type." 
    ::= { cmedxEphemeralTermStatsEntry 3 }
 

-- *********************************************************************

-- cmedxCommandProcStatsTable

-- *********************************************************************

cmedxCommandProcStatsTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxCommandProcStatsEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This table provides the statistics related to H.248
            command processing on a media gateway link.
            "
    ::= { cmedxStats 6 }

cmedxCommandProcStatsEntry OBJECT-TYPE
    SYNTAX          CmedxCommandProcStatsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "The information in each entry is for a media gateway link.
            "
    INDEX           {
                        cmedGatewayId,
                        cmedGatewayLinkId
                    } 
    ::= { cmedxCommandProcStatsTable 1 }

CmedxCommandProcStatsEntry ::= SEQUENCE {
        cmedxCmdPhyTermAddRespTimeMin   Gauge32,
        cmedxCmdPhyTermAddRespTimeMax   Gauge32,
        cmedxCmdPhyTermAddRespTimeAvg   Gauge32,
        cmedxCmdPhyTermAddRespTimeCount Gauge32,
        cmedxCmdPhyTermModRespTimeMin   Gauge32,
        cmedxCmdPhyTermModRespTimeMax   Gauge32,
        cmedxCmdPhyTermModRespTimeAvg   Gauge32,
        cmedxCmdPhyTermModRespTimeCount Gauge32,
        cmedxCmdPhyTermSubRespTimeMin   Gauge32,
        cmedxCmdPhyTermSubRespTimeMax   Gauge32,
        cmedxCmdPhyTermSubRespTimeAvg   Gauge32,
        cmedxCmdPhyTermSubRespTimeCount Gauge32,
        cmedxCmdEphTermAddRespTimeMin   Gauge32,
        cmedxCmdEphTermAddRespTimeMax   Gauge32,
        cmedxCmdEphTermAddRespTimeAvg   Gauge32,
        cmedxCmdEphTermAddRespTimeCount Gauge32,
        cmedxCmdEphTermModRespTimeMin   Gauge32,
        cmedxCmdEphTermModRespTimeMax   Gauge32,
        cmedxCmdEphTermModRespTimeAvg   Gauge32,
        cmedxCmdEphTermModRespTimeCount Gauge32,
        cmedxCmdEphTermSubRespTimeMin   Gauge32,
        cmedxCmdEphTermSubRespTimeMax   Gauge32,
        cmedxCmdEphTermSubRespTimeAvg   Gauge32,
        cmedxCmdEphTermSubRespTimeCount Gauge32,
        cmedxCmdNumInProgCmds           Gauge32,
        cmedxCmdMaxInProgCmds           Gauge32,
        cmedxCmdSinceLastReset          Unsigned32
}

cmedxCmdPhyTermAddRespTimeMin OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The minimum add response time (ms) for physical
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 1 }

cmedxCmdPhyTermAddRespTimeMax OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The maximum add response time (ms) for physical
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 2 }

cmedxCmdPhyTermAddRespTimeAvg OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The average add response time (ms) for physical
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 3 }

cmedxCmdPhyTermAddRespTimeCount OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The number of add responses for physical terminations
            which have been sent during the statistics interval
            on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 4 }

cmedxCmdPhyTermModRespTimeMin OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The minimum modify response time (ms) for physical
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 5 }

cmedxCmdPhyTermModRespTimeMax OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The maximum modify response time (ms) for physical
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 6 }

cmedxCmdPhyTermModRespTimeAvg OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The average modify response time (ms) for physical
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 7 }

cmedxCmdPhyTermModRespTimeCount OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The number of modify responses for physical terminations
            which have been sent during the statistics interval
            on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 8 }

cmedxCmdPhyTermSubRespTimeMin OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The minimum subtract response time (ms) for physical
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 9 }

cmedxCmdPhyTermSubRespTimeMax OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The maximum subtract response time (ms) for physical
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 10 }

cmedxCmdPhyTermSubRespTimeAvg OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The average subtract response time (ms) for physical
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 11 }

cmedxCmdPhyTermSubRespTimeCount OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The number of subtract responses for physical terminations
            which have been sent during the statistics interval
            on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 12 }

cmedxCmdEphTermAddRespTimeMin OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The minimum add response time (ms) for ephemeral
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 13 }

cmedxCmdEphTermAddRespTimeMax OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The maximum add response time (ms) for ephemeral
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 14 }

cmedxCmdEphTermAddRespTimeAvg OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The average add response time (ms) for ephemeral
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 15 }

cmedxCmdEphTermAddRespTimeCount OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The number of add responses for ephemeral terminations
            which have been sent during the statistics interval
            on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 16 }

cmedxCmdEphTermModRespTimeMin OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The minimum modify response time (ms) for ephemeral
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 17 }

cmedxCmdEphTermModRespTimeMax OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The maximum modify response time (ms) for ephemeral
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 18 }

cmedxCmdEphTermModRespTimeAvg OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The average modify response time (ms) for ephemeral
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 19 }

cmedxCmdEphTermModRespTimeCount OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The number of modify responses for ephemeral terminations
            which have been sent during the statistics interval
            on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 20 }

cmedxCmdEphTermSubRespTimeMin OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The minimum subtract response time (ms) for ephemeral
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 21 }

cmedxCmdEphTermSubRespTimeMax OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The maximum subtract response time (ms) for ephemeral
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 22 }

cmedxCmdEphTermSubRespTimeAvg OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The average subtract response time (ms) for ephemeral
            terminations on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 23 }

cmedxCmdEphTermSubRespTimeCount OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The number of subtract responses for ephemeral terminations
            which have been sent during the statistics interval
            on a media gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 24 }

cmedxCmdNumInProgCmds OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The number of in-progress commands on a media gateway link." 
    ::= { cmedxCommandProcStatsEntry 25 }

cmedxCmdMaxInProgCmds OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The maximum number of in-progress commands on a media
            gateway link.
            " 
    ::= { cmedxCommandProcStatsEntry 26 }

cmedxCmdSinceLastReset OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The elapsed time (in seconds) from the last periodic reset.

            All (non-accumulator) statistic objects were zeroed on 
            the last reset.
            " 
    ::= { cmedxCommandProcStatsEntry 27 }
 

-- *****************************************************************

-- cmedxOverloadStatsTable

-- *****************************************************************

cmedxOverloadStatsTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxOverloadStatsEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This table contains statistics related to gateway overload
            control (H.248.11)."
    ::= { cmedxStats 7 }

cmedxOverloadStatsEntry OBJECT-TYPE
    SYNTAX          CmedxOverloadStatsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "Each entry contains the statistics of gateway overload
            control."
    INDEX           { cmedGatewayId } 
    ::= { cmedxOverloadStatsTable 1 }

CmedxOverloadStatsEntry ::= SEQUENCE {
        cmedxOverloadEnterCounts   Counter32SinceReset,
        cmedxOverloadExitCounts    Counter32SinceReset,
        cmedxOverloadCurrentState  INTEGER ,
        cmedxOverloadLastResetTime TimeStamp,
        cmedxOverloadCountersClear TruthValue
}

cmedxOverloadEnterCounts OBJECT-TYPE
    SYNTAX          Counter32SinceReset
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The number of times that the gateway enters the
            overload condition because of any of CAC monitoring
            resources has exceeded the medium threshold 
            specified by the value of ccacSysRpMedThreshold
            since the last counter reset." 
    ::= { cmedxOverloadStatsEntry 1 }

cmedxOverloadExitCounts OBJECT-TYPE
    SYNTAX          Counter32SinceReset
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The number of times that the gateway exits the
            overload condition when all of CAC monitoring
            resources have fallen below the low threshold 
            specified by the value of ccacSysRpLowThreshold
            since the last counter reset." 
    ::= { cmedxOverloadStatsEntry 2 }

cmedxOverloadCurrentState OBJECT-TYPE
    SYNTAX          INTEGER  {
                        normal(1),
                        overload(2)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object indicates the current overload state
            of the gateway.
            normal   - In normal condition.
            overload - In overload condition. " 
    ::= { cmedxOverloadStatsEntry 3 }

cmedxOverloadLastResetTime OBJECT-TYPE
    SYNTAX          TimeStamp
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object contains the value of sysUpTime when
            the last counter reset occurred by setting
            cmedxOverloadCountersClear to 'true'.

            If no counter reset has occurred since the last time
            the media gateway reboot, this object will contain
            value of zero." 
    ::= { cmedxOverloadStatsEntry 4 }

cmedxOverloadCountersClear OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
            "When this object is to set value of true(1), all
            statistics counters in the table cmedxOverloadStatsTable
            will be reset to zero.

            Setting this object to a value of false(2) has no
            implication.

            This object will always return 'false' upon any SNMP get
            operation." 
    ::= { cmedxOverloadStatsEntry 5 }
 

-- *****************************************************************

-- cmedxOverloadResourceStatsTable

-- *****************************************************************

cmedxOverloadResourceStatsTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxOverloadResourceStatsEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This table contains the statistics of the resource
            utilization when the gateway enters overload condition."
    ::= { cmedxStats 8 }

cmedxOverloadResourceStatsEntry OBJECT-TYPE
    SYNTAX          CmedxOverloadResourceStatsEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "Each entry contains the utilization statistics of
            the resource when the gateway is overloaded."
    INDEX           {
                        cmedGatewayId,
                        cmedxOverloadRsResourceIndex
                    } 
    ::= { cmedxOverloadResourceStatsTable 1 }

CmedxOverloadResourceStatsEntry ::= SEQUENCE {
        cmedxOverloadRsResourceIndex   Unsigned32,
        cmedxOverloadRsHighCounts      Counter32SinceReset,
        cmedxOverloadRsMedCounts       Counter32SinceReset,
        cmedxOverloadRsLowCounts       Counter32SinceReset,
        cmedxOverloadContributorCounts Counter32SinceReset,
        cmedxOverloadRsLastResetTime   TimeStamp,
        cmedxOverloadRsCountersClear   TruthValue
}

cmedxOverloadRsResourceIndex OBJECT-TYPE
    SYNTAX          Unsigned32 (0..1000 )
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This object uniquely identifies the utilization
            of the resource is monitored for the gateway overload.

            The value of 0 is to sum the individual statistical 
            counter for all the monitored resources." 
    ::= { cmedxOverloadResourceStatsEntry 1 }

cmedxOverloadRsHighCounts OBJECT-TYPE
    SYNTAX          Counter32SinceReset
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The accumulated number of times that the utilization
            of the resource is above the high threshold specified 
            by ccacSysRpHighThreshold when the gateway enters 
            the overload condition since the last counter reset." 
    ::= { cmedxOverloadResourceStatsEntry 2 }

cmedxOverloadRsMedCounts OBJECT-TYPE
    SYNTAX          Counter32SinceReset
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The accumulated number of times that the utilization
            of the resource is above the medium threshold specified
            by ccacSysRpMedThreshold when the gateway enters the 
            overload condition since the last counter reset." 
    ::= { cmedxOverloadResourceStatsEntry 3 }

cmedxOverloadRsLowCounts OBJECT-TYPE
    SYNTAX          Counter32SinceReset
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The accumulated number of times that the utilization
            of the resource is above the low threshold specified 
            by ccacSysRpLowThreshold when the gateway enters 
            the overload condition since the last counter reset." 
    ::= { cmedxOverloadResourceStatsEntry 4 }

cmedxOverloadContributorCounts OBJECT-TYPE
    SYNTAX          Counter32SinceReset
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The accumulated number of times the CAC monitoring
            resource causes the gateway entering the overload 
            condition since the last counter reset." 
    ::= { cmedxOverloadResourceStatsEntry 5 }

cmedxOverloadRsLastResetTime OBJECT-TYPE
    SYNTAX          TimeStamp
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object contains the value of sysUpTime when
            the last counter reset occurred by setting
            cmedxOverloadRsCountersClear to 'true'.

            If no counter reset has occurred since the last time
            the media gateway reboot, this object will contain
            value of zero." 
    ::= { cmedxOverloadResourceStatsEntry 6 }

cmedxOverloadRsCountersClear OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
            "When this object is to set value of true(1), all
            statistics counters in the table 
            cmedxOverloadResourceStatsTable will be reset to zero.

            Setting this object to a value of false(2) has no
            implication.

            This object will always return 'false' upon any SNMP get
            operation." 
    ::= { cmedxOverloadResourceStatsEntry 7 }
 

-- *****************************************************************

-- cmedxEphemeralTermStatsInfoTable

-- *****************************************************************

cmedxEphemeralTermStatsInfoTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF CmedxEphemeralTermStatsInfoEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This table contains statistics information related to
            ephemeral terminations."
    ::= { cmedxStats 9 }

cmedxEphemeralTermStatsInfoEntry OBJECT-TYPE
    SYNTAX          CmedxEphemeralTermStatsInfoEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "Each entry contains the ephemeral termination statistics
            inforamtion for a specific level.
            "
    INDEX           { cmedxEphTermInfoStatsIndex } 
    ::= { cmedxEphemeralTermStatsInfoTable 1 }

CmedxEphemeralTermStatsInfoEntry ::= SEQUENCE {
        cmedxEphTermInfoStatsIndex     Unsigned32,
        cmedxEphTermInfoStatsIndexType INTEGER ,
        cmedxEphTermInfoNumTerm        Counter32SinceReset,
        cmedxEphTermInfoNumInUsed      Gauge32,
        cmedxEphTermInfoMaxNumInUsed   Gauge32,
        cmedxEphTermInfoMinDuration    Gauge32,
        cmedxEphTermInfoMaxDuration    Gauge32,
        cmedxEphTermInfoAvgDuration    Gauge32,
        cmedxEphTermInfoCounterClear   TruthValue,
        cmedxEphTermInfoSinceLastClear Unsigned32,
        cmedxEphTermInfoSinceLastReset Unsigned32,
        cmedxEphTermIndexInfo          Unsigned32,
        cmedxEphTermInfoNumFreed       Unsigned32
}

cmedxEphTermInfoStatsIndex OBJECT-TYPE
    SYNTAX          Unsigned32 (1..2147483647 )
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
            "This object uniquely identifies the entry to store ephemeral
            termination statistics information.
            " 
    ::= { cmedxEphemeralTermStatsInfoEntry 1 }

cmedxEphTermInfoStatsIndexType OBJECT-TYPE
    SYNTAX          INTEGER  {
                        bpvc(1),
                        gw(2),
                        vgw(3)
                    }
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object is used to indicate index
            ('cmedxEphTermInfoStatsIndex') type.
            " 
    ::= { cmedxEphemeralTermStatsInfoEntry 2 }

cmedxEphTermInfoNumTerm OBJECT-TYPE
    SYNTAX          Counter32SinceReset
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The accumulated number of ephemeral
            termination.
            " 
    ::= { cmedxEphemeralTermStatsInfoEntry 3 }

cmedxEphTermInfoNumInUsed OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The number of ephemeral termination currently
            in use.
            " 
    ::= { cmedxEphemeralTermStatsInfoEntry 4 }

cmedxEphTermInfoMaxNumInUsed OBJECT-TYPE
    SYNTAX          Gauge32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The high watermark of number of ephemeral termination
            in use.
            " 
    ::= { cmedxEphemeralTermStatsInfoEntry 5 }

cmedxEphTermInfoMinDuration OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The minimum duration of ephemeral termination.
            " 
    ::= { cmedxEphemeralTermStatsInfoEntry 6 }

cmedxEphTermInfoMaxDuration OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The maximum duration of ephemeral termination.
            " 
    ::= { cmedxEphemeralTermStatsInfoEntry 7 }

cmedxEphTermInfoAvgDuration OBJECT-TYPE
    SYNTAX          Gauge32
    UNITS           "ms"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The average duration of ephemeral termination.
            " 
    ::= { cmedxEphemeralTermStatsInfoEntry 8 }

cmedxEphTermInfoCounterClear OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-write
    STATUS          current
    DESCRIPTION
            "When this object is set to value of true(1), all statistics
            counters with type of Counter32SinceReset in this table
            will be reset to zero. 

            Setting this object to a value of false(2) has no implication.

            This object will always return 'false' upon any SNMP 
            get operation. 
            " 
    ::= { cmedxEphemeralTermStatsInfoEntry 9 }

cmedxEphTermInfoSinceLastClear OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "minutes"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The elapsed time from the last counter clear.

            The following objects are set to zero on the
            last counter clear:

                'cmedxEphTermInfoNumTerm'
            " 
    ::= { cmedxEphemeralTermStatsInfoEntry 10 }

cmedxEphTermInfoSinceLastReset OBJECT-TYPE
    SYNTAX          Unsigned32
    UNITS           "seconds"
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "The elapsed time from the last reset.

            The following objects are set to zero on the
            last reset:

                'cmedxEphTermInfoNumInUsed'
                'cmedxEphTermInfoMaxNumInUsed'
                'cmedxEphTermInfoMinDuration'
                'cmedxEphTermInfoMaxDuration'
                'cmedxEphTermInfoNumFreed'
            " 
    ::= { cmedxEphemeralTermStatsInfoEntry 11 }

cmedxEphTermIndexInfo OBJECT-TYPE
    SYNTAX          Unsigned32 (0..2147483647 )
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "This object is used to store the index
            ('cmedxEphTermInfoStatsIndex') related information. 
            Example: for bpvc ('cmedxEphTermInfoStatsIndexType'), 
            the vpi and vci are stored in this object.
            The value zero means this object should be ignored.
            " 
    ::= { cmedxEphemeralTermStatsInfoEntry 12 }

cmedxEphTermInfoNumFreed OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
            "Total number of ephemeral terminations that have been
            freed.
            " 
    ::= { cmedxEphemeralTermStatsInfoEntry 13 }
 

-- *****************************************************************

-- Conformance for the CiSCO-MEGACO-EXT-MIB

-- *****************************************************************
ciscoMegacoExtConformance  OBJECT IDENTIFIER
    ::= { ciscoMegacoExtMIB 2 }

cmedxCompliances  OBJECT IDENTIFIER
    ::= { ciscoMegacoExtConformance 1 }

cmedxGroups  OBJECT IDENTIFIER
    ::= { ciscoMegacoExtConformance 2 }


cmedxCompliance MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
            "Compliance statement for entities which implement
            the CiSCO-MEGACO-EXT-MIB.
            This has been replaced by cmedxComplianceRev1"
    MODULE          -- this module
    MANDATORY-GROUPS {
                        cmedxConfigGroup,
                        cmedxStatsGroup,
                        cmedxCallReduceRateGroup
                    }

    GROUP           cmedxCodecNegotiationGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports CODEC negotiation."
    ::= { cmedxCompliances 1 }

cmedxComplianceRev1 MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
            "Compliance statement for entities which implement
            the CiSCO-MEGACO-EXT-MIB.
            This has been replaced by cmedxComplianceRev2."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        cmedxConfigGroup,
                        cmedxStatsGroup,
                        cmedxCallReduceRateGroup
                    }

    GROUP           cmedxCodecNegotiationGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports CODEC negotiation."

    GROUP           cmedxConfigExtGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports Megaco message size
            provisioning and BellCore standard COT. "

    GROUP           cmedxServiceStateGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports graceful out-of-service
            and cancel graceful out-of-service."
    ::= { cmedxCompliances 2 }

cmedxComplianceRev2 MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
            "Compliance statement for entities which implement
            the CiSCO-MEGACO-EXT-MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        cmedxConfigGroupRev1,
                        cmedxStatsGroup,
                        cmedxCallReduceRateGroup
                    }

    GROUP           cmedxCodecNegotiationGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports CODEC negotiation."

    GROUP           cmedxConfigExtGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports Megaco message size
            provisioning and BellCore standard COT. "

    GROUP           cmedxServiceStateGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports graceful out-of-service
            and cancel graceful out-of-service."

    GROUP           cmedxCallReduceRateNotifyGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports H.248.10 congestion
            control notification."

    GROUP           cmedxOverloadControlGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports H.248.11 overload
            control package ."

    GROUP           cmedxOverloadStatsGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports H.248.11 overload
            control statistics."

    GROUP           cmedxStatsExtGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports extended statistics."

    GROUP           cmedxEphemeralTermStatsGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports ephemeral termination 
            statistics."
    ::= { cmedxCompliances 3 }

cmedxComplianceRev3 MODULE-COMPLIANCE
    STATUS          deprecated
    DESCRIPTION
            "Compliance statement for entities which implement
            the CiSCO-MEGACO-EXT-MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        cmedxConfigGroupRev2,
                        cmedxStatsGroupRev1,
                        cmedxCallReduceRateGroup
                    }

    GROUP           cmedxCodecNegotiationGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports CODEC negotiation."

    GROUP           cmedxConfigExtGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports Megaco message size
            provisioning and BellCore standard COT. "

    GROUP           cmedxServiceStateGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports graceful out-of-service
            and cancel graceful out-of-service."

    GROUP           cmedxCallReduceRateNotifyGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports H.248.10 congestion
            control notification."

    GROUP           cmedxOverloadControlGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports H.248.11 overload
            control package ."

    GROUP           cmedxOverloadStatsGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports H.248.11 overload
            control statistics."

    GROUP           cmedxStatsExtGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports extended statistics."

    GROUP           cmedxEphemeralTermStatsGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports ephemeral termination 
            statistics."
    ::= { cmedxCompliances 4 }

cmedxComplianceRev4 MODULE-COMPLIANCE
    STATUS          current
    DESCRIPTION
            "Compliance statement for entities which implement
            the CiSCO-MEGACO-EXT-MIB."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        cmedxConfigGroupRev2,
                        cmedxStatsGroupRev1,
                        cmedxCallReduceRateGroup,
                        cmedxConfigDomainInfoGroup
                    }

    GROUP           cmedxCodecNegotiationGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports CODEC negotiation."

    GROUP           cmedxConfigExtGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports Megaco message size
            provisioning and BellCore standard COT. "

    GROUP           cmedxServiceStateGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports graceful out-of-service
            and cancel graceful out-of-service."

    GROUP           cmedxCallReduceRateNotifyGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports H.248.10 congestion
            control notification."

    GROUP           cmedxOverloadControlGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports H.248.11 overload
            control package ."

    GROUP           cmedxOverloadStatsGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports H.248.11 overload
            control statistics."

    GROUP           cmedxStatsExtGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports extended statistics."

    GROUP           cmedxEphemeralTermStatsGroup
    DESCRIPTION
            "Implementation of this group is mandatory for the
            media gateway if it supports ephemeral termination 
            statistics."
    ::= { cmedxCompliances 5 }

-- Units of Conformance
cmedxConfigGroup OBJECT-GROUP
    OBJECTS         {
                        cmedxGatewayMgcGroupIndex,
                        cmedxGatewayIpAddressIndex,
                        cmedxGatewayAssociationId,
                        cmedxGatewayMaxContexts,
                        cmedxGatewayMaxTermsInContext,
                        cmedxGatewayMgExecTime,
                        cmedxGatewayMgcExecTime,
                        cmedxGatewayProvisionRespTime,
                        cmedxGatewayNumConnRetries,
                        cmedxGatewayMaxWaitingDelay,
                        cmedxGatewayRestartDelay,
                        cmedxGatewayRespRetentionTime,
                        cmedxGatewayInitialRtt,
                        cmedxGatewayInactivityTime,
                        cmedxGatewayHeaderAddrType,
                        cmedxGatewayDownServiceDelay,
                        cmedxGatewayActiveMgcAddress,
                        cmedxGatewayActiveMgcDomain,
                        cmedxGatewayActiveMgcPortNum,
                        cmedxGatewayStateChangeReason,
                        cmedxGatewayStateChangeMethod,
                        cmedxTermType,
                        cmedxTermTypeProfileId,
                        cmedxTermTypePkgIds,
                        cmedxTermTypeRowStatus,
                        cmedxProfilePlayCpToneInterDur,
                        cmedxProfileDtmfDigitOnDur,
                        cmedxProfileDtmfPauseDur,
                        cmedxProfileCot1Frequency,
                        cmedxProfileCot2Frequency,
                        cmedxProfileInitiateCotDur,
                        cmedxProfileRespCotMethod,
                        cmedxProfileDetectLongCpToneDur,
                        cmedxProfileDetectLongDigitDur,
                        cmedxProfileEchoCancelEnabled,
                        cmedxProfileEchoCancelTail,
                        cmedxProfileInGainControl,
                        cmedxProfileOutAttnControl,
                        cmedxProfileVoIpVadEnabled,
                        cmedxProfileVoIpVadTimer,
                        cmedxProfileVoAal2VadTimer,
                        cmedxProfileAtmBearerType,
                        cmedxProfileAtmAalPartialFill,
                        cmedxProfileAtmAalType,
                        cmedxProfileSuppressBearerDigit,
                        cmedxProfileRowStatus
                    }
    STATUS          deprecated
    DESCRIPTION
            "This group contains of all the configuration extended
            information for a media gateway."
    ::= { cmedxGroups 1 }

cmedxStatsGroup OBJECT-GROUP
    OBJECTS         {
                        cmedxGatewayLastEvent,
                        cmedxCmdNumAddFails,
                        cmedxCmdNumAddSucceeds,
                        cmedxCmdNumSubtractFails,
                        cmedxCmdNumSubtractSucceeds,
                        cmedxCmdNumMoveFails,
                        cmedxCmdNumMoveSucceeds,
                        cmedxCmdNumModifyFails,
                        cmedxCmdNumModifySucceeds,
                        cmedxCmdNumAuditValFails,
                        cmedxCmdNumAuditValSucceeds,
                        cmedxCmdNumAuditCapFails,
                        cmedxCmdNumAuditCapSucceeds,
                        cmedxCmdNumNotifyFails,
                        cmedxCmdNumNotifySucceeds,
                        cmedxCmdNumSrvChgFromMgcFails,
                        cmedxCmdNumSrvChgFromMgcSucceeds,
                        cmedxCmdNumSrvChgFromMgFails,
                        cmedxCmdNumSrvChgFromMgSucceeds,
                        cmedxCntxNumActiveContexts,
                        cmedxCntxPeakNumActiveContexts,
                        cmedxCntxNumContextAllocated,
                        cmedxCntxNumContextFreed,
                        cmedxCntxShortestContextLife,
                        cmedxCntxAverageContextLife,
                        cmedxCntxLongestContextLife,
                        cmedxCntxNumCntxMoreThan2Terms,
                        cmedxPhyTermStatsNumAdds,
                        cmedxPhyTermStatsNumFailures,
                        cmedxPhyTermStatsOosFromMgcs,
                        cmedxPhyTermStatsOosFromOams,
                        cmedxEphTermStatsNumAdds,
                        cmedxEphTermStatsNumFailures
                    }
    STATUS          deprecated
    DESCRIPTION
            "This group contains of all the statistics information
            for the statistics in a media gateway."
    ::= { cmedxGroups 2 }

cmedxCallReduceRateGroup OBJECT-GROUP
    OBJECTS         {
                        cmedxCallCongEnabled,
                        cmedxCallRenotifInterval,
                        cmedxCRRNumOfLevel,
                        cmedxCurrentCRR,
                        cmedxCallReduceRate
                    }
    STATUS          current
    DESCRIPTION
            "This group contains objects used to manage and/or monitor
            the rate at which call attempts are made by Media 
            gateway controller on this Media Gateway. "
    ::= { cmedxGroups 3 }

cmedxCodecNegotiationGroup OBJECT-GROUP
    OBJECTS         { cmedxCodecNegotiationPreference }
    STATUS          current
    DESCRIPTION
            "This group contains objects used for CODEC
            negotiation between MG and MGC."
    ::= { cmedxGroups 4 }

cmedxConfigExtGroup OBJECT-GROUP
    OBJECTS         {
                        cmedxGatewayDynamicTpktVersion,
                        cmedxGatewayMaxCommandMsgSize,
                        cmedxGatewayMaxReplyMsgSize,
                        cmedxProfileOriginatingCotTx,
                        cmedxProfileOriginatingCotRx,
                        cmedxProfileTerminatingCotTx,
                        cmedxProfileTerminatingCotRx
                    }
    STATUS          current
    DESCRIPTION
            "This group contains of the objects related to
            Megaco message size provisioning and
            BellCore standard COT a media gateway."
    ::= { cmedxGroups 5 }

cmedxServiceStateGroup OBJECT-GROUP
    OBJECTS         {
                        cmedxGatewayAdminAction,
                        cmedxGatewayServiceState
                    }
    STATUS          current
    DESCRIPTION
            "This group contains of the objects to change the
            service state of a media gateway."
    ::= { cmedxGroups 6 }

cmedxConfigGroupRev1 OBJECT-GROUP
    OBJECTS         {
                        cmedxGatewayMgcGroupIndex,
                        cmedxGatewayIpAddressIndex,
                        cmedxGatewayAssociationId,
                        cmedxGatewayMaxContexts,
                        cmedxGatewayMaxTermsInContext,
                        cmedxGatewayMgExecTime,
                        cmedxGatewayMgcExecTime,
                        cmedxGatewayProvisionRespTime,
                        cmedxGatewayNumConnRetries,
                        cmedxGatewayMaxWaitingDelay,
                        cmedxGatewayRestartDelay,
                        cmedxGatewayRespRetentionTime,
                        cmedxGatewayInitialRtt,
                        cmedxGatewayInactivityTime,
                        cmedxGatewayHeaderAddrType,
                        cmedxGatewayDownServiceDelay,
                        cmedxGatewayActiveMgcAddress,
                        cmedxGatewayActiveMgcDomain,
                        cmedxGatewayActiveMgcPortNum,
                        cmedxGatewayStateChangeReason,
                        cmedxGatewayStateChangeMethod,
                        cmedxTermType,
                        cmedxTermTypeProfileId,
                        cmedxTermTypePkgIds,
                        cmedxTermTypeRowStatus,
                        cmedxProfilePlayCpToneInterDur,
                        cmedxProfileDtmfDigitOnDur,
                        cmedxProfileDtmfPauseDur,
                        cmedxProfileCot1Frequency,
                        cmedxProfileCot2Frequency,
                        cmedxProfileInitiateCotDur,
                        cmedxProfileRespCotMethod,
                        cmedxProfileDetectLongCpToneDur,
                        cmedxProfileDetectLongDigitDur,
                        cmedxProfileEchoCancelEnabled,
                        cmedxProfileEchoCancelTail,
                        cmedxProfileInGainControl,
                        cmedxProfileOutAttnControl,
                        cmedxProfileVoIpVadEnabled,
                        cmedxProfileVoIpVadTimer,
                        cmedxProfileVoAal2VadTimer,
                        cmedxProfileAtmBearerType,
                        cmedxProfileAtmAalPartialFill,
                        cmedxProfileAtmAalType,
                        cmedxProfileSuppressBearerDigit,
                        cmedxProfileRowStatus,
                        cmedxProfileComfortNoiseGenerate,
                        cmedxGatewaySctpAssocId,
                        cmedxGatewaySrvChgProfile,
                        cmedxGatewaySrvChgProfileVer,
                        cmedxGatewayMsgTokenType
                    }
    STATUS          deprecated
    DESCRIPTION
            "This group contains of all the configuration extended
            information for a media gateway."
    ::= { cmedxGroups 7 }

cmedxCallReduceRateNotifyGroup OBJECT-GROUP
    OBJECTS         {
                        cmedxCrrNotifyState,
                        cmedxCrrNotifyEnabled,
                        cmedxCurrentCallState
                    }
    STATUS          current
    DESCRIPTION
            "This group contains objects used for H.248.10 congestion
            control notification."
    ::= { cmedxGroups 8 }

cmedxOverloadControlGroup OBJECT-GROUP
    OBJECTS         {
                        cmedxOverloadControlEnabled,
                        cmedxOverloadNotifyState,
                        cmedxOverloadNotifyEnabled
                    }
    STATUS          current
    DESCRIPTION
            "This group contains objects used for H.248.11 overload
            control package."
    ::= { cmedxGroups 9 }

cmedxOverloadStatsGroup OBJECT-GROUP
    OBJECTS         {
                        cmedxOverloadEnterCounts,
                        cmedxOverloadExitCounts,
                        cmedxOverloadCurrentState,
                        cmedxOverloadLastResetTime,
                        cmedxOverloadCountersClear,
                        cmedxOverloadRsHighCounts,
                        cmedxOverloadRsMedCounts,
                        cmedxOverloadRsLowCounts,
                        cmedxOverloadContributorCounts,
                        cmedxOverloadRsLastResetTime,
                        cmedxOverloadRsCountersClear
                    }
    STATUS          current
    DESCRIPTION
            "This group contains objects used for the statistics of
            H.248.11 overload control."
    ::= { cmedxGroups 10 }

cmedxStatsExtGroup OBJECT-GROUP
    OBJECTS         {
                        cmedxCmdTotalFails,
                        cmedxCmdTotalSucceeds,
                        cmedxCmdTotal,
                        cmedxCmdTotalPendings,
                        cmedxCmdPhyTermAddRespTimeMin,
                        cmedxCmdPhyTermAddRespTimeMax,
                        cmedxCmdPhyTermAddRespTimeAvg,
                        cmedxCmdPhyTermAddRespTimeCount,
                        cmedxCmdPhyTermModRespTimeMin,
                        cmedxCmdPhyTermModRespTimeMax,
                        cmedxCmdPhyTermModRespTimeAvg,
                        cmedxCmdPhyTermModRespTimeCount,
                        cmedxCmdPhyTermSubRespTimeMin,
                        cmedxCmdPhyTermSubRespTimeMax,
                        cmedxCmdPhyTermSubRespTimeAvg,
                        cmedxCmdPhyTermSubRespTimeCount,
                        cmedxCmdEphTermAddRespTimeMin,
                        cmedxCmdEphTermAddRespTimeMax,
                        cmedxCmdEphTermAddRespTimeAvg,
                        cmedxCmdEphTermAddRespTimeCount,
                        cmedxCmdEphTermModRespTimeMin,
                        cmedxCmdEphTermModRespTimeMax,
                        cmedxCmdEphTermModRespTimeAvg,
                        cmedxCmdEphTermModRespTimeCount,
                        cmedxCmdEphTermSubRespTimeMin,
                        cmedxCmdEphTermSubRespTimeMax,
                        cmedxCmdEphTermSubRespTimeAvg,
                        cmedxCmdEphTermSubRespTimeCount,
                        cmedxCmdNumInProgCmds,
                        cmedxCmdMaxInProgCmds,
                        cmedxCmdSinceLastReset
                    }
    STATUS          current
    DESCRIPTION
            "This group contains objects related to the extended
            statistics of H.248."
    ::= { cmedxGroups 11 }

cmedxEphemeralTermStatsGroup OBJECT-GROUP
    OBJECTS         {
                        cmedxEphTermInfoStatsIndexType,
                        cmedxEphTermInfoNumTerm,
                        cmedxEphTermInfoNumInUsed,
                        cmedxEphTermInfoMaxNumInUsed,
                        cmedxEphTermInfoMinDuration,
                        cmedxEphTermInfoMaxDuration,
                        cmedxEphTermInfoAvgDuration,
                        cmedxEphTermInfoCounterClear,
                        cmedxEphTermInfoSinceLastClear,
                        cmedxEphTermInfoSinceLastReset,
                        cmedxEphTermIndexInfo,
                        cmedxEphTermInfoNumFreed
                    }
    STATUS          current
    DESCRIPTION
            "This group contains objects related to ephemeral
            termination statistics of H.248."
    ::= { cmedxGroups 12 }

cmedxConfigGroupRev2 OBJECT-GROUP
    OBJECTS         {
                        cmedxGatewayMgcGroupIndex,
                        cmedxGatewayIpAddressIndex,
                        cmedxGatewayAssociationId,
                        cmedxGatewayMaxContexts,
                        cmedxGatewayMaxTermsInContext,
                        cmedxGatewayMgExecTime,
                        cmedxGatewayMgcExecTime,
                        cmedxGatewayNumConnRetries,
                        cmedxGatewayMaxWaitingDelay,
                        cmedxGatewayRestartDelay,
                        cmedxGatewayRespRetentionTime,
                        cmedxGatewayInitialRtt,
                        cmedxGatewayInactivityTime,
                        cmedxGatewayHeaderAddrType,
                        cmedxGatewayDownServiceDelay,
                        cmedxGatewayActiveMgcAddress,
                        cmedxGatewayActiveMgcDomain,
                        cmedxGatewayActiveMgcPortNum,
                        cmedxGatewayStateChangeReason,
                        cmedxGatewayStateChangeMethod,
                        cmedxTermType,
                        cmedxTermTypeProfileId,
                        cmedxTermTypePkgIds,
                        cmedxTermTypeRowStatus,
                        cmedxProfilePlayCpToneInterDur,
                        cmedxProfileDtmfDigitOnDur,
                        cmedxProfileDtmfPauseDur,
                        cmedxProfileCot1Frequency,
                        cmedxProfileCot2Frequency,
                        cmedxProfileInitiateCotDur,
                        cmedxProfileRespCotMethod,
                        cmedxProfileDetectLongCpToneDur,
                        cmedxProfileDetectLongDigitDur,
                        cmedxProfileEchoCancelEnabled,
                        cmedxProfileEchoCancelTail,
                        cmedxProfileInGainControl,
                        cmedxProfileOutAttnControl,
                        cmedxProfileVoIpVadEnabled,
                        cmedxProfileVoIpVadTimer,
                        cmedxProfileVoAal2VadTimer,
                        cmedxProfileAtmBearerType,
                        cmedxProfileAtmAalPartialFill,
                        cmedxProfileAtmAalType,
                        cmedxProfileSuppressBearerDigit,
                        cmedxProfileRowStatus,
                        cmedxProfileComfortNoiseGenerate,
                        cmedxGatewaySctpAssocId,
                        cmedxGatewaySrvChgProfile,
                        cmedxGatewaySrvChgProfileVer,
                        cmedxGatewayMsgTokenType,
                        cmedxGatewayMgProvisionRspTime,
                        cmedxGatewayMgcProvisionRspTime,
                        cmedxGatewayMgOrigPendLimit,
                        cmedxGatewayMgcOrigPendLimit
                    }
    STATUS          current
    DESCRIPTION
            "This group contains of all the configuration extended
            information for a media gateway."
    ::= { cmedxGroups 13 }

cmedxStatsGroupRev1 OBJECT-GROUP
    OBJECTS         {
                        cmedxGatewayLastEvent,
                        cmedxCmdNumAddFails,
                        cmedxCmdNumAddSucceeds,
                        cmedxCmdNumSubtractFails,
                        cmedxCmdNumSubtractSucceeds,
                        cmedxCmdNumMoveFails,
                        cmedxCmdNumMoveSucceeds,
                        cmedxCmdNumModifyFails,
                        cmedxCmdNumModifySucceeds,
                        cmedxCmdNumAuditValFails,
                        cmedxCmdNumAuditValSucceeds,
                        cmedxCmdNumAuditCapFails,
                        cmedxCmdNumAuditCapSucceeds,
                        cmedxCmdNumNotifyFails,
                        cmedxCmdNumNotifySucceeds,
                        cmedxCmdNumSrvChgFromMgcFails,
                        cmedxCmdNumSrvChgFromMgcSucceeds,
                        cmedxCmdNumSrvChgFromMgFails,
                        cmedxCmdNumSrvChgFromMgSucceeds,
                        cmedxCntxNumActiveContexts,
                        cmedxCntxPeakNumActiveContexts,
                        cmedxCntxNumContextAllocated,
                        cmedxCntxNumContextFreed,
                        cmedxCntxShortestContextLife,
                        cmedxCntxAverageContextLife,
                        cmedxCntxLongestContextLife,
                        cmedxCntxNumCntxMoreThan2Terms,
                        cmedxPhyTermStatsNumAdds,
                        cmedxPhyTermStatsNumFailures,
                        cmedxPhyTermStatsOosFromMgcs,
                        cmedxPhyTermStatsOosFromOams,
                        cmedxEphTermStatsNumAdds,
                        cmedxEphTermStatsNumFailures,
                        cmedxCmdNumAddPendings,
                        cmedxCmdNumSubtractPendings,
                        cmedxCmdNumMovePendings,
                        cmedxCmdNumModifyPendings,
                        cmedxCmdNumAuditValPendings,
                        cmedxCmdNumAuditCapPendings,
                        cmedxCmdNumNotifyPendings,
                        cmedxCmdNumSrvChgFromMgcPendings,
                        cmedxCmdNumSrvChgFromMgPendings
                    }
    STATUS          current
    DESCRIPTION
            "This group contains of all the statistics information
            for the statistics in a media gateway."
    ::= { cmedxGroups 14 }

cmedxConfigDomainInfoGroup OBJECT-GROUP
    OBJECTS         {
                        cmedxGatewayDomainName,
                        cmedxGatewayCmbDnAndPortInMID
                    }
    STATUS          current
    DESCRIPTION
            "This group specifies the domain name and port
            configuration for a media gateway."
    ::= { cmedxGroups 15 }

END